Anaphylactic Shock Following Nonionic Contrast Medium During Caudal Epidural Injection

Overview
Journal Korean J Pain
Date 2015 Oct 24
PMID 26495083
Citations 4
Authors
Affiliations
Soon will be listed here.
Abstract

Caudal epidural injection is a common intervention in patients with low back pain and sciatica. Even though the complications of fluoroscopically directed epidural injections are less frequent than in blind epidural injections, complications due to contrast media can occur. We report a case of anaphylactic shock immediately after injection of an intravenous nonionic contrast medium (iohexol) during the caudal epidural injection for low back pain and sciatica in a patient without a previous allergic history to ionic contrast media (ioxitalamate). Five minutes after the dye was injected, the patient began to experience dizziness, and the systolic blood pressure dropped to 60 mmHg. Subsequently, the patient exhibited a mild drowsy mental state. About 30 minutes after the subcutaneous injection of 0.2 mg epinephrine, the systolic blood pressure increased to 90 mmHg. The patient recovered without any sequela. Life-threatening complications after injection of intravenous contrast medium require immediate treatment.

Citing Articles

Radiocontrast medium induces histamine release in association with upregulation of miR‑19a‑3p and miR‑362‑3p expression.

Chang W, Huang P, Li C, Huang H, Chou T, Liao E Biomed Rep. 2024; 20(6):93.

PMID: 38765857 PMC: 11099600. DOI: 10.3892/br.2024.1780.


Fatal Anaphylaxis to Contrast a Reality: A Case Report.

Sapra A, Bhandari P, Manek M, Gupta S, Sharma S Cureus. 2020; 11(11):e6214.

PMID: 31890415 PMC: 6929239. DOI: 10.7759/cureus.6214.


Discordant lumbar epidural hematoma after caudal steroid injection: A case report (CARE-compliant).

Choi J, Chang Y, Jung W, Lee K, Kim J, Jo Y Medicine (Baltimore). 2017; 96(24):e7127.

PMID: 28614233 PMC: 5478318. DOI: 10.1097/MD.0000000000007127.


The Use of Contrast in Caudal Epidural Injections under Image Intensifier Guidance: Is It Necessary?.

Naidoo K, Alazzawi S, Montgomery A Clin Orthop Surg. 2017; 9(2):190-192.

PMID: 28567221 PMC: 5435657. DOI: 10.4055/cios.2017.9.2.190.

References
1.
Delaney A, Carter A, Fisher M . The prevention of anaphylactoid reactions to iodinated radiological contrast media: a systematic review. BMC Med Imaging. 2006; 6:2. PMC: 1475567. DOI: 10.1186/1471-2342-6-2. View

2.
Doo A, Kim J, Lee J, Han Y, Son J . A Comparison of Two Techniques for Ultrasound-guided Caudal Injection: The Influence of the Depth of the Inserted Needle on Caudal Block. Korean J Pain. 2015; 28(2):122-8. PMC: 4387457. DOI: 10.3344/kjp.2015.28.2.122. View

3.
Bush Jr W, Mullarkey M, Webb D . Adverse reactions to radiographic contrast material. West J Med. 1980; 132(2):95-8. PMC: 1271975. View

4.
Katayama H, Yamaguchi K, Kozuka T, Takashima T, Seez P, Matsuura K . Adverse reactions to ionic and nonionic contrast media. A report from the Japanese Committee on the Safety of Contrast Media. Radiology. 1990; 175(3):621-8. DOI: 10.1148/radiology.175.3.2343107. View

5.
Manchikanti L, Malla Y, Wargo B, Cash K, Pampati V, Fellows B . A prospective evaluation of complications of 10,000 fluoroscopically directed epidural injections. Pain Physician. 2012; 15(2):131-40. View