» Articles » PMID: 26474107

Electrochemical Detection of Single Phospholipid Vesicle Collisions at a Pt Ultramicroelectrode

Overview
Journal Langmuir
Specialty Chemistry
Date 2015 Oct 17
PMID 26474107
Citations 13
Authors
Affiliations
Soon will be listed here.
Abstract

We report the collision behavior of single unilamellar vesicles, composed of a bilayer lipid membrane (BLM), on a platinum (Pt) ultramicroelectrode (UME) by two electrochemical detection methods. In the first method, the blocking of a solution redox reaction, induced by the single vesicle adsorption on the Pt UME, can be observed in the amperometric i-t response as current steps during the electrochemical oxidation of ferrocyanide. In the second technique, the ferrocyanide redox probe is directly encapsulated inside vesicles and can be oxidized during the vesicle collision on the UME if the potential is poised positive enough for ferrocyanide oxidation to occur. In the amperometric i-t response for the latter experiment, a current spike is observed. Here, we report the vesicle blocking (VB) method as a relevant technique for determining the vesicle solution concentration from the collisional frequency and also for observing the vesicle adhesion on the Pt surface. In addition, vesicle reactor (VR) experiments show clear evidence that the lipid bilayer membrane does not collapse or break open at the Pt UME during the vesicle collision. Because the bilayer is too thick for electron tunneling to occur readily, an appropriate concentration of a surfactant, such as Triton X-100 (TX100), was added in the VR solution to induce loosening of the bilayer (transfection conditions), allowing the electrode to oxidize the contents of the vesicle. With this technique, the TX100 effect on the vesicle lipid bilayer permeability can be evaluated through the current spike charge and frequency corresponding to redox vesicle collisions.

Citing Articles

Computer-Assisted Processing of Current Step Signals in Single Blocking Impact Electrochemistry.

Langlard A, Smida H, Chevalet R, Thobie-Gautier C, Boujtita M, Lebegue E ACS Meas Sci Au. 2024; 4(5):585-592.

PMID: 39430961 PMC: 11487761. DOI: 10.1021/acsmeasuresciau.4c00046.


The role of applied potential on particle sizing precision in single-entity blocking electrochemistry.

Liu E, Popescu S, Eden A, Chung J, Roehrich B, Sepunaru L Electrochim Acta. 2024; 472.

PMID: 39070043 PMC: 11283758. DOI: 10.1016/j.electacta.2023.143397.


Electrochemical Characterization of Neurotransmitters in a Single Submicron Droplet.

Park H, Park J Biosensors (Basel). 2024; 14(2).

PMID: 38392021 PMC: 10886559. DOI: 10.3390/bios14020102.


Electrochemical Analysis of Attoliter Water Droplets in Organic Solutions through Partitioning Equilibrium.

Moon H, Park J Sensors (Basel). 2023; 23(4).

PMID: 36850752 PMC: 9959340. DOI: 10.3390/s23042157.


Trends in single-impact electrochemistry for bacteria analysis.

Smida H, Langlard A, Ameline D, Thobie-Gautier C, Boujtita M, Lebegue E Anal Bioanal Chem. 2023; 415(18):3717-3725.

PMID: 36754873 DOI: 10.1007/s00216-023-04568-z.