Prevalence and Molecular Characteristics of Waterborne Pathogen Legionella in Industrial Cooling Tower Environments
Overview
Public Health
Authors
Affiliations
Cooling towers are a source of Legionnaires' disease. It is important from a public health perspective to survey industrial cooling towers for the presence of Legionella. Prospective surveillance of the extent of Legionella pollution was conducted at factories in Shijiazhuang, China between March 2011 and September 2012. Overall, 35.7% of 255 industrial cooling tower water samples showed Legionella-positive, and their concentrations ranged from 100 Colony-Forming Units (CFU)/liter to 88,000 CFU/liter, with an average concentration of 9100 CFU/liter. A total of 121 isolates were obtained. All isolates were L. pneumophila, and the isolated serogroups included serogroups 1 (68 isolates, 56.2%), 6 (25, 20.7%), 5 (12, 9.9%), 8 (8, 6.6%), 3 (6, 5.0%) and 9 (2, 1.6%). All 121 isolates were analyzed by pulsed-field gel electrophoresis (PFGE) and 64 different patterns were obtained. All 121 isolates were analyzed sequence-based typing (SBT), a full 7-allele profile was obtained from 117 isolates. One hundred and seventeen isolates were divided into 49 sequence types. Two virulence genes, lvh and rtxA, are analyzed by polymerase chain reaction (PCR). 92.6% (112/121) and 98.3% (119/121) isolates carried lvh and rtxA respectively and 90.9% (110/121) of tested isolates carried both genes. Our results demonstrated high prevalence and genetic polymorphism of L. pneumophila in industrial cooling tower environments in Shijiazhang, China, and the SBT and virulence gene PCR results suggested that the isolates were pathogenic. Improved control and prevention strategies are urgently needed.
Logan-Jackson A, Rose J Microorganisms. 2022; 10(1).
PMID: 35056530 PMC: 8778510. DOI: 10.3390/microorganisms10010081.
Tsao H, Scheikl U, Herbold C, Indra A, Walochnik J, Horn M Water Res. 2019; 159:464-479.
PMID: 31128471 PMC: 6554697. DOI: 10.1016/j.watres.2019.04.028.
Analysis of Genetic Characterization and Clonality of Isolated from Cooling Towers in Japan.
Nakanishi N, Nomoto R, Tanaka S, Arikawa K, Iwamoto T Int J Environ Res Public Health. 2019; 16(9).
PMID: 31086119 PMC: 6540132. DOI: 10.3390/ijerph16091664.
Tabatabaei M, Hemati Z, Moezzi M, Azimzadeh N Mol Biol Res Commun. 2017; 5(4):215-223.
PMID: 28261625 PMC: 5326485.
Zhang L, Li Y, Wang X, Shangguan Z, Zhou H, Wu Y Int J Environ Res Public Health. 2017; 14(3).
PMID: 28245548 PMC: 5369058. DOI: 10.3390/ijerph14030222.