A Large Legionnaires' Disease Outbreak in Pamplona, Spain: Early Detection, Rapid Control and No Case Fatality

Abstract

An outbreak of Legionnaire's disease was detected in Pamplona, Spain, on 1 June 2006. Patients with pneumonia were tested to detect Legionella pneumophila antigen in urine (Binax Now; Binax Inc., Scarborough, ME, USA), and all 146 confirmed cases were interviewed. The outbreak was related to district 2 (22 012 inhabitants), where 45% of the cases lived and 50% had visited; 5% lived in neighbouring districts. The highest incidence was found in the resident population of district 2 (3/1000 inhabitants), section 2 (14/1000). All 31 cooling towers of district 2 were analysed. L. pneumophila antigen (Binax Now) was detected in four towers, which were closed on 2 June. Only the strain isolated in a tower situated in section 2 of district 2 matched all five clinical isolates, as assessed by mAb and two genotyping methods, AFLP and PFGE. Eight days after closing the towers, new cases ceased appearing. Early detection and rapid coordinated medical and environmental actions permitted immediate control of the outbreak and probably contributed to the null case fatality.

Citing Articles

Multi-Scale Airborne Infectious Disease Transmission.

Dillon C, Dillon M Appl Environ Microbiol. 2020; 87(4).

PMID: 33277266 PMC: 7851691. DOI: 10.1128/AEM.02314-20.


Water Management for Construction: Evidence for Risk Characterization in Community and Healthcare Settings: A Systematic Review.

Scanlon M, Gordon J, McCoy W, Cain M Int J Environ Res Public Health. 2020; 17(6).

PMID: 32214051 PMC: 7143259. DOI: 10.3390/ijerph17062168.


Outbreaks of Legionnaires' Disease and Pontiac Fever 2006-2017.

Hamilton K, Prussin 2nd A, Ahmed W, Haas C Curr Environ Health Rep. 2018; 5(2):263-271.

PMID: 29744757 DOI: 10.1007/s40572-018-0201-4.


The unprecedented 2014 Legionnaires' disease outbreak in Portugal: atmospheric driving mechanisms.

Russo A, Gouveia C, Soares P, Cardoso R, Mendes M, Trigo R Int J Biometeorol. 2018; 62(7):1167-1179.

PMID: 29572569 DOI: 10.1007/s00484-018-1520-8.


Legionnaires' Disease Outbreaks and Cooling Towers, New York City, New York, USA.

Fitzhenry R, Weiss D, Cimini D, Balter S, Boyd C, Alleyne L Emerg Infect Dis. 2017; 23(11).

PMID: 29049017 PMC: 5652439. DOI: 10.3201/eid2311.161584.


References
1.
Fry N, Bangsborg J, Bernander S, Etienne J, Forsblom B, Gaia V . Assessment of intercentre reproducibility and epidemiological concordance of Legionella pneumophila serogroup 1 genotyping by amplified fragment length polymorphism analysis. Eur J Clin Microbiol Infect Dis. 2000; 19(10):773-80. DOI: 10.1007/s100960000359. View

2.
Burnsed L, Hicks L, Smithee L, Fields B, Bradley K, Pascoe N . A large, travel-associated outbreak of legionellosis among hotel guests: utility of the urine antigen assay in confirming Pontiac fever. Clin Infect Dis. 2006; 44(2):222-8. DOI: 10.1086/510387. View

3.
Benin A, Benson R, Besser R . Trends in legionnaires disease, 1980-1998: declining mortality and new patterns of diagnosis. Clin Infect Dis. 2002; 35(9):1039-46. DOI: 10.1086/342903. View

4.
Helbig J, Bernander S, Pastoris M, Etienne J, Gaia V, Lauwers S . Pan-European study on culture-proven Legionnaires' disease: distribution of Legionella pneumophila serogroups and monoclonal subgroups. Eur J Clin Microbiol Infect Dis. 2002; 21(10):710-6. DOI: 10.1007/s10096-002-0820-3. View

5.
Garcia-Fulgueiras A, Navarro C, Fenoll D, Garcia J, Gonzalez-Diego P, Jimenez-Bunuales T . Legionnaires' disease outbreak in Murcia, Spain. Emerg Infect Dis. 2003; 9(8):915-21. PMC: 3020623. DOI: 10.3201/eid0908.030337. View