» Articles » PMID: 26462294

-Nitroso--acetylpenicillamine (SNAP) Impregnated Silicone Foley Catheters: A Potential Biomaterial/Device To Prevent Catheter-Associated Urinary Tract Infections

Overview
Date 2015 Oct 14
PMID 26462294
Citations 44
Authors
Affiliations
Soon will be listed here.
Abstract

Urinary Foley catheters are utilized for management of hospitalized patients and are associated with high rates of urinary tract infections (UTIs). Nitric oxide (NO) potently inhibits microbial biofilm formation, which is the primary cause of catheter associated UTIs (CAUTIs). Herein, commercial silicone Foley catheters are impregnated via a solvent swelling method with -nitroso--acetyl-D-penicillamine (SNAP), a synthetic NO donor that exhibits long-term NO release and stability when incorporated into low water-uptake polymers. The proposed catheters generate NO surface-fluxes >0.7 × 10 mol min cm for over one month under physiological conditions, with minimal SNAP leaching. These biomedical devices are demonstrated to significantly decrease formation of biofilm on the surface of the catheter tubings over 3, 7, and 14 day periods by microbial species ( and ) commonly causing CAUTIs. Toxicity assessment demonstrates that the SNAP-impregnated catheters are fully biocompatible, as extracts of the catheter tubings score 0 on a 3-point grading scale using an accepted mouse fibroblast cell-line toxicity model. Consequently, SNAP-impregnated silicone Foley catheters can likely provide an efficient strategy to greatly reduce the occurrence of nosocomial CAUTIs.

Citing Articles

Anti-Infective Bacteriophage Immobilized Nitric Oxide-Releasing Surface for Prevention of Thrombosis and Device-Associated Infections.

Gondil V, Ashcraft M, Ghalei S, Kumar A, Wilson S, Devine R ACS Appl Bio Mater. 2025; 8(2):1362-1376.

PMID: 39895136 PMC: 11836933. DOI: 10.1021/acsabm.4c01638.


Investigation of the susceptibility of clinical infection loads to nitric oxide antibacterial treatment.

Estes Bright L, Mondal A, Pinon V, Kumar A, Thompson S, Brisbois E Nitric Oxide. 2024; 154():19-28.

PMID: 39561942 PMC: 11729576. DOI: 10.1016/j.niox.2024.11.003.


Synthesis and Characterization of a Sustained Nitric Oxide-Releasing Orthodontic Elastomeric Chain for Antimicrobial Action.

McDonald A, Warden C, Tan J, Piell K, Steinbach-Rankins J, Janakiraman N Int J Mol Sci. 2024; 25(13).

PMID: 39000090 PMC: 11241501. DOI: 10.3390/ijms25136982.


Nitric oxide releasing coatings for the prevention of viral and bacterial infections.

Aveyard J, Richards S, Li M, Pitt G, Hughes G, Akpan A Biomater Sci. 2024; 12(18):4664-4681.

PMID: 38980705 PMC: 11385708. DOI: 10.1039/d4bm00172a.


Preventing Surgical Site Infections with a Nitric Oxide-Releasing Poly(lactic acid--glycolic acid) Suture Material.

Griffin L, Garren M, Maffe P, Ghalei S, Brisbois E, Handa H ACS Appl Bio Mater. 2024; 7(5):3086-3095.

PMID: 38652779 PMC: 11110049. DOI: 10.1021/acsabm.4c00128.


References
1.
Privett B, Deupree S, Backlund C, Rao K, Johnson C, Coneski P . Synergy of nitric oxide and silver sulfadiazine against gram-negative, gram-positive, and antibiotic-resistant pathogens. Mol Pharm. 2010; 7(6):2289-96. PMC: 2997881. DOI: 10.1021/mp100248e. View

2.
Mah T, OToole G . Mechanisms of biofilm resistance to antimicrobial agents. Trends Microbiol. 2001; 9(1):34-9. DOI: 10.1016/s0966-842x(00)01913-2. View

3.
Maki D, Tambyah P . Engineering out the risk for infection with urinary catheters. Emerg Infect Dis. 2001; 7(2):342-7. PMC: 2631699. DOI: 10.3201/eid0702.010240. View

4.
Ren H, Wu J, Xi C, Lehnert N, Major T, Bartlett R . Electrochemically modulated nitric oxide (NO) releasing biomedical devices via copper(II)-Tri(2-pyridylmethyl)amine mediated reduction of nitrite. ACS Appl Mater Interfaces. 2014; 6(6):3779-83. PMC: 3969097. DOI: 10.1021/am406066a. View

5.
Tenke P, Koves B, Johansen T . An update on prevention and treatment of catheter-associated urinary tract infections. Curr Opin Infect Dis. 2013; 27(1):102-7. DOI: 10.1097/QCO.0000000000000031. View