» Articles » PMID: 26452351

Determination of Angiotensin-(1-7) with HPLC/Fluorescence-Detection

Overview
Journal J Fluoresc
Specialties Biophysics
Chemistry
Date 2015 Oct 11
PMID 26452351
Citations 1
Authors
Affiliations
Soon will be listed here.
Abstract

Angiotensin-(1-7) is an important active component in the renin-angiotensin-system. Due to its cardio protective effects it is now under investigation in combination with antioxidants as a reperfusion solution. The combination showed impressive effects on isolated hearts of male Wistar rats after induced ischemia. In this work a high performance liquid chromatography method with fluorescence detection was developed for the first time for in-process measurements as well as for stability tests of the peptide in the novel antioxidant-containing Karal® solution. For fluorescence detection of angiotensin-(1-7) fluorescamine as derivatization dye was applied. Under optimized conditions the method showed linearity over the range of 50 to 5000 ng/mL with R(2) of 0.9988 and an overall precision better than 5.0 %. LOD and LOQ were determined to be in the femtomol range on column. It was found that stability of angiotensin-(1-7) could be significantly improved in the antioxidant containing preparation compared to aqueous solutions.

Citing Articles

Angiotensin-(1-7) Participates in Enhanced Skeletal Muscle Insulin Sensitivity After a Bout of Exercise.

Echeverria-Rodriguez O, Gallardo-Ortiz I, Del Valle-Mondragon L, Villalobos-Molina R J Endocr Soc. 2020; 4(2):bvaa007.

PMID: 32104748 PMC: 7039407. DOI: 10.1210/jendso/bvaa007.

References
1.
Ali Q, Wu Y, Nag S, Hussain T . Estimation of angiotensin peptides in biological samples by LC/MS method. Anal Methods. 2014; 6(1):215-222. PMC: 3904384. DOI: 10.1039/C3AY41305E. View

2.
Pelegrini-da-Silva A, Prado W, Juliano M, Wilk S, Martins A . High-performance liquid chromatographic separation of renin-angiotensin system peptides and most of their metabolic fragments. J Chromatogr B Analyt Technol Biomed Life Sci. 2002; 780(2):301-7. DOI: 10.1016/s1570-0232(02)00542-1. View

3.
Senanayake P, Moriguchi A, Kumagai H, Ganten D, Ferrario C, Brosnihan K . Increased expression of angiotensin peptides in the brain of transgenic hypertensive rats. Peptides. 1994; 15(5):919-26. DOI: 10.1016/0196-9781(94)90051-5. View

4.
Buha S, Panchal A, Panchal H, Chambhare R, Kumar S, Jain M . HPLC-FLD for the simultaneous determination of primary and secondary amino acids from complex biological sample by pre-column derivatization. J Chromatogr Sci. 2011; 49(2):118-23. DOI: 10.1093/chrsci/49.2.118. View

5.
Bujak-Gizycka B, Madej J, Wolkow P, Olszanecki R, Drabik L, Rutowski J . Measurement of angiotensin metabolites in organ bath and cell culture experiments by liquid chromatography - electrospray ionization - mass spectrometry (LC-ESI-MS). J Physiol Pharmacol. 2007; 58(3):529-40. View