» Articles » PMID: 26442606

Chemiluminometric Immunosensor for High-Sensitivity Cardiac Troponin I Employing a Polymerized Enzyme Conjugate As a Tracer

Overview
Journal Sci Rep
Specialty Science
Date 2015 Oct 8
PMID 26442606
Citations 5
Authors
Affiliations
Soon will be listed here.
Abstract

To detect high-sensitivity cardiac troponin I (hs-cTnI; <0.01 ng/mL) at points of care, we developed a rapid immunosensor by using horseradish peroxidase polymerized in 20 molecules on average (Poly-HRP) as a tracer conjugated with streptavidin (SA-Poly-HRP). As shown in the conventional system, enhanced sensitivity could be achieved by using a sequential binding scheme for the complex formation to contain the huge molecular tracer. We used a 2-dimensional chromatographic technology to carry out the sequential bindings in cross-flow directions. After the complex formation of antigen-antibody with analyte in a vertical direction, SA-Poly-HRP was horizontally supplied across the membrane strip for additional binding via a biotin-SA linkage. The HRP substrate was subsequently supplied along the same direction to produce a chemiluminometric signal, which was measured by a cooled charge-coupled device. Hs-cTnI analysis was completed in this format within 25 min, and the results showed a high correlation with those of the CentaurXP® reference system (R(2) > 0.99). The detection limit of the rapid immunosensor was 0.003 ± 0.001 ng/mL cTnI, corresponding to a 10-fold improvement compared to results using the plain enzyme tracer. This demonstrated the measurement of hs-cTnI in a much more cost-effective manner compared to the automated versions currently available.

Citing Articles

Post-Assay Chemical Enhancement for Highly Sensitive Lateral Flow Immunoassays: A Critical Review.

Panferov V, Zherdev A, Dzantiev B Biosensors (Basel). 2023; 13(9).

PMID: 37754100 PMC: 10526817. DOI: 10.3390/bios13090866.


Silver-enhanced colloidal gold dip strip immunoassay integrated with smartphone-based colorimetry for sensitive detection of cardiac marker troponin I.

Poosinuntakul N, Chanmee T, Porntadavity S, Chailapakul O, Apilux A Sci Rep. 2022; 12(1):19866.

PMID: 36400826 PMC: 9674838. DOI: 10.1038/s41598-022-24458-1.


Development of Liposome-Based Immunoassay for the Detection of Cardiac Troponin I.

Radha R, Al-Sayah M Molecules. 2021; 26(22).

PMID: 34834080 PMC: 8623906. DOI: 10.3390/molecules26226988.


The role of antibody-based troponin detection in cardiovascular disease: A critical assessment.

Ma H, Cassedy A, OKennedy R J Immunol Methods. 2021; 497:113108.

PMID: 34329690 PMC: 8412434. DOI: 10.1016/j.jim.2021.113108.


Improving the sensitivity of traditional Western blotting via Streptavidin containing Poly-horseradish peroxidase (PolyHRP).

Mishra M, Tiwari S, Gunaseelan A, Li D, Hammock B, Gomes A Electrophoresis. 2019; 40(12-13):1731-1739.

PMID: 31021001 PMC: 7036291. DOI: 10.1002/elps.201900059.

References
1.
Anderson J, Adams C, Antman E, Bridges C, Califf R, Casey Jr D . 2011 ACCF/AHA Focused Update Incorporated Into the ACC/AHA 2007 Guidelines for the Management of Patients With Unstable Angina/Non-ST-Elevation Myocardial Infarction: a report of the American College of Cardiology Foundation/American Heart.... Circulation. 2011; 123(18):e426-579. DOI: 10.1161/CIR.0b013e318212bb8b. View

2.
Thygesen K, Mair J, Katus H, Plebani M, Venge P, Collinson P . Recommendations for the use of cardiac troponin measurement in acute cardiac care. Eur Heart J. 2010; 31(18):2197-204. DOI: 10.1093/eurheartj/ehq251. View

3.
Sato Y, Fujiwara H, Takatsu Y . Cardiac troponin and heart failure in the era of high-sensitivity assays. J Cardiol. 2012; 60(3):160-7. DOI: 10.1016/j.jjcc.2012.06.007. View

4.
Apple F, Saenger A . The state of cardiac troponin assays: looking bright and moving in the right direction. Clin Chem. 2013; 59(7):1014-6. DOI: 10.1373/clinchem.2013.203307. View

5.
Palamalai V, Murakami M, Apple F . Diagnostic performance of four point of care cardiac troponin I assays to rule in and rule out acute myocardial infarction. Clin Biochem. 2013; 46(16-17):1631-5. DOI: 10.1016/j.clinbiochem.2013.06.026. View