» Articles » PMID: 26417528

Direct Regularization from Co-registered Anatomical Images for MRI-guided Near-infrared Spectral Tomographic Image Reconstruction

Overview
Specialty Radiology
Date 2015 Sep 30
PMID 26417528
Citations 20
Authors
Affiliations
Soon will be listed here.
Abstract

Combining anatomical information from high resolution imaging modalities to guide near-infrared spectral tomography (NIRST) is an efficient strategy for improving the quality of the reconstructed spectral images. A new approach for incorporating image information directly into the inversion matrix regularization was examined using Direct Regularization from Images (DRI), which encodes the gray-scale data into the NIRST image reconstruction problem. This process has the benefit of eliminating user intervention such as image segmentation of distinct regions. Specifically, the Dynamic Contrast Enhanced Magnetic Resonance (DCE-MR) image intensity value differences within the anatomical image were used to implement an exponentially-weighted regularization function between the image pixels. The algorithm was validated using simulated reconstructions with noise, and the results showed that spatial resolution and robustness of the reconstructed images were significantly improved by appropriate choice of the regularization weight parameters. The proposed approach was also tested on in vivo breast data acquired in a recent clinical trial combining NIRST / MRI for cancer tumor characterization. Relative to the standard "no priors" diffuse recovery, the contrast of the tumor to the normal surrounding tissue increased from 2.4 to 3.6, and the difference between the tumor size segmented from DCE-MR images and reconstructed optical images decreased from 18% to 6%, while there was an overall decrease in surface artifacts.

Citing Articles

FDU-Net: Deep Learning-Based Three-Dimensional Diffuse Optical Image Reconstruction.

Deng B, Gu H, Zhu H, Chang K, Hoebel K, Patel J IEEE Trans Med Imaging. 2023; 42(8):2439-2450.

PMID: 37028063 PMC: 10446911. DOI: 10.1109/TMI.2023.3252576.


Selfrec-Net: self-supervised deep learning approach for the reconstruction of Cherenkov-excited luminescence scanned tomography.

Zhang W, Hu T, Li Z, Sun Z, Jia K, Dou H Biomed Opt Express. 2023; 14(2):783-798.

PMID: 36874507 PMC: 9979688. DOI: 10.1364/BOE.480429.


Method to improve the localization accuracy and contrast recovery of lesions in separately acquired X-ray and diffuse optical tomographic breast imaging.

Muldoon A, Kabeer A, Cormier J, Saksena M, Fang Q, Carp S Biomed Opt Express. 2022; 13(10):5295-5310.

PMID: 36425617 PMC: 9664870. DOI: 10.1364/BOE.470373.


Deep-learning based image reconstruction for MRI-guided near-infrared spectral tomography.

Feng J, Zhang W, Li Z, Jia K, Jiang S, Dehghani H Optica. 2022; 9(3):264-267.

PMID: 35340570 PMC: 8952193. DOI: 10.1364/optica.446576.


Evaluation of a pipeline for simulation, reconstruction, and classification in ultrasound-aided diffuse optical tomography of breast tumors.

Di Sciacca G, Maffeis G, Farina A, Dalla Mora A, Pifferi A, Taroni P J Biomed Opt. 2022; 27(3).

PMID: 35332743 PMC: 8943242. DOI: 10.1117/1.JBO.27.3.036003.


References
1.
Brooksby B, Jiang S, Dehghani H, Pogue B, Paulsen K, Weaver J . Combining near-infrared tomography and magnetic resonance imaging to study in vivo breast tissue: implementation of a Laplacian-type regularization to incorporate magnetic resonance structure. J Biomed Opt. 2005; 10(5):051504. DOI: 10.1117/1.2098627. View

2.
Shaw C, Yalavarthy P . Prior image-constrained ℓ(1)-norm-based reconstruction method for effective usage of structural information in diffuse optical tomography. Opt Lett. 2012; 37(20):4353-5. DOI: 10.1364/OL.37.004353. View

3.
Azar F, Lee K, Khamene A, Choe R, Corlu A, Konecky S . Standardized platform for coregistration of nonconcurrent diffuse optical and magnetic resonance breast images obtained in different geometries. J Biomed Opt. 2007; 12(5):051902. DOI: 10.1117/1.2798630. View

4.
Fang Q, Moore R, Kopans D, Boas D . Compositional-prior-guided image reconstruction algorithm for multi-modality imaging. Biomed Opt Express. 2011; 1(1):223-235. PMC: 3005170. DOI: 10.1364/boe.1.000223. View

5.
Mastanduno M, El-Ghussein F, Jiang S, diFlorio-Alexander R, Junqing X, Hong Y . Adaptable near-infrared spectroscopy fiber array for improved coupling to different breast sizes during clinical MRI. Acad Radiol. 2014; 21(2):141-50. PMC: 4778710. DOI: 10.1016/j.acra.2013.09.025. View