Validation of the Hexoskin Wearable Vest During Lying, Sitting, Standing, and Walking Activities

Overview
Date 2015 Sep 12
PMID 26360814
Citations 59
Authors
Affiliations
Soon will be listed here.
Abstract

We tested the validity of the Hexoskin wearable vest to monitor heart rate (HR), breathing rate (BR), tidal volume (VT), minute ventilation, and hip motion intensity (HMI) in comparison with laboratory standard devices during lying, sitting, standing, and walking. Twenty healthy young volunteers participated in this study. First, participants walked 6 min on a treadmill at speeds of 1, 3, and 4.5 km/h followed by increasing treadmill grades until 80% of their predicted maximal heart rate. Second, lying, sitting, and standing tasks were performed (5 min each) followed by 6 min of treadmill walking at 80% of their ventilatory threshold. Analysis of each individual's mean values under each resting or exercise condition by the 2 measurement systems revealed low coefficient of variation and high intraclass correlation values for HR, BR, and HMI. The Bland-Altman results from HR, BR, and HMI indicated no deviation of the mean value from zero and relatively small variability about the mean. VT and minute ventilation were provided in arbitrary units by the Hexoskin device; however, relative magnitude of change from Hexoskin closely tracked the laboratory standard method. Hexoskin presented low variability, good agreement, and consistency. The Hexoskin wearable vest was a valid and consistent tool to monitor activities typical of daily living such as different body positions (lying, sitting, and standing) and various walking speeds.

Citing Articles

Wearable devices for patient monitoring in the intensive care unit.

Angelucci A, Greco M, Cecconi M, Aliverti A Intensive Care Med Exp. 2025; 13(1):26.

PMID: 40016479 PMC: 11868008. DOI: 10.1186/s40635-025-00738-8.


Speech Detection via Respiratory Inductance Plethysmography, Thoracic Impedance, Accelerometers, and Gyroscopes: A Machine Learning-Informed Comparative Study.

Saygin M, Schoenmakers M, Gevonden M, de Geus E Psychophysiology. 2025; 62(2):e70021.

PMID: 39950497 PMC: 11826986. DOI: 10.1111/psyp.70021.


Study on the stability and accuracy of the new Booster portable cardiopulmonary function meter.

Yun H, Zhang W, Yu C, Li Q, Song Y Front Physiol. 2025; 15():1453942.

PMID: 39844896 PMC: 11751217. DOI: 10.3389/fphys.2024.1453942.


Mindfulness Exercises Reduce Acute Physiologic Stress Among Female Clinicians.

Wolfe A, Hinds P, du Plessis A, Gordish-Dressman H, Freedenberg V, Soghier L Crit Care Explor. 2024; 6(11):e1171.

PMID: 39466161 PMC: 11519409. DOI: 10.1097/CCE.0000000000001171.


Skin sensing and wearable technology as tools to measure atopic dermatitis severity.

Khan Y, Todorov A, Torah R, Beeby S, Ardern-Jones M Skin Health Dis. 2024; 4(5):e449.

PMID: 39355726 PMC: 11442081. DOI: 10.1002/ski2.449.