» Articles » PMID: 26329642

Robust and Highly Performant Ring Detection Algorithm for 3d Particle Tracking Using 2d Microscope Imaging

Overview
Journal Sci Rep
Specialty Science
Date 2015 Sep 3
PMID 26329642
Citations 3
Authors
Affiliations
Soon will be listed here.
Abstract

Three-dimensional particle tracking is an essential tool in studying dynamics under the microscope, namely, fluid dynamics in microfluidic devices, bacteria taxis, cellular trafficking. The 3d position can be determined using 2d imaging alone by measuring the diffraction rings generated by an out-of-focus fluorescent particle, imaged on a single camera. Here I present a ring detection algorithm exhibiting a high detection rate, which is robust to the challenges arising from ring occlusion, inclusions and overlaps, and allows resolving particles even when near to each other. It is capable of real time analysis thanks to its high performance and low memory footprint. The proposed algorithm, an offspring of the circle Hough transform, addresses the need to efficiently trace the trajectories of many particles concurrently, when their number in not necessarily fixed, by solving a classification problem, and overcomes the challenges of finding local maxima in the complex parameter space which results from ring clusters and noise. Several algorithmic concepts introduced here can be advantageous in other cases, particularly when dealing with noisy and sparse data. The implementation is based on open-source and cross-platform software packages only, making it easy to distribute and modify. It is implemented in a microfluidic experiment allowing real-time multi-particle tracking at 70 Hz, achieving a detection rate which exceeds 94% and only 1% false-detection.

Citing Articles

Calcium signals are necessary to establish auxin transporter polarity in a plant stem cell niche.

Li T, Yan A, Bhatia N, Altinok A, Afik E, Durand-Smet P Nat Commun. 2019; 10(1):726.

PMID: 30760714 PMC: 6374474. DOI: 10.1038/s41467-019-08575-6.


On the role of initial velocities in pair dispersion in a microfluidic chaotic flow.

Afik E, Steinberg V Nat Commun. 2017; 8(1):468.

PMID: 28883492 PMC: 5589773. DOI: 10.1038/s41467-017-00389-8.


Radiative decay engineering 8: Coupled emission microscopy for lens-free high-throughput fluorescence detection.

Zhu L, Badugu R, Zhang D, Wang R, Descrovi E, Lakowicz J Anal Biochem. 2017; 531:20-36.

PMID: 28527910 PMC: 5530754. DOI: 10.1016/j.ab.2017.05.020.

References
1.
McMullen J, Jensen K . Integrated microreactors for reaction automation: new approaches to reaction development. Annu Rev Anal Chem (Palo Alto Calif). 2010; 3:19-42. DOI: 10.1146/annurev.anchem.111808.073718. View

2.
Amini H, Sollier E, Weaver W, Di Carlo D . Intrinsic particle-induced lateral transport in microchannels. Proc Natl Acad Sci U S A. 2012; 109(29):11593-8. PMC: 3406876. DOI: 10.1073/pnas.1207550109. View

3.
Burghelea T, Segre E, Bar-Joseph I, Groisman A, Steinberg V . Chaotic flow and efficient mixing in a microchannel with a polymer solution. Phys Rev E Stat Nonlin Soft Matter Phys. 2004; 69(6 Pt 2):066305. DOI: 10.1103/PhysRevE.69.066305. View

4.
Cheong F, Krishnatreya B, Grier D . Strategies for three-dimensional particle tracking with holographic video microscopy. Opt Express. 2010; 18(13):13563-73. DOI: 10.1364/OE.18.013563. View

5.
deMello A . Control and detection of chemical reactions in microfluidic systems. Nature. 2006; 442(7101):394-402. DOI: 10.1038/nature05062. View