» Articles » PMID: 26253383

Usefulness of IDEAL T2 Imaging for Homogeneous Fat Suppression and Reducing Susceptibility Artefacts in Brachial Plexus MRI at 3.0 T

Overview
Journal Radiol Med
Specialty Radiology
Date 2015 Aug 9
PMID 26253383
Citations 5
Authors
Affiliations
Soon will be listed here.
Abstract

Purpose: To quantitatively and qualitatively compare fat-suppressed MR imaging quality using iterative decomposition of water and fat with echo asymmetry and least-squares estimation (IDEAL) with that using frequency-selective fat-suppressed (FSFS) T2 images of the brachial plexus at 3.0 T.

Materials And Methods: Prospective MR image analysis was performed in 40 volunteers and 40 patients at a single centre. Oblique-sagittal and coronal IDEAL fat-suppressed T2 images and FSFS T2 images were compared. Visual assessment was performed by two independent musculoskeletal radiologists with respect to: (1) susceptibility artefacts around the neck, (2) homogeneity of fat suppression, (3) image sharpness and (4) tissue resolution contrast of pathologies. The signal-to-noise ratios (SNR) for each image sequence were assessed.

Results: Compared to FSFS sequences, IDEAL fat-suppressed T2 images significantly reduced artefacts around the brachial plexus and significantly improved homogeneous fat suppression (p < 0.05). IDEAL significantly improved sharpness and lesion-to-tissue contrast (p < 0.05). The mean SNRs were significantly improved on T2-weighted IDEAL images (p < 0.05).

Conclusion: IDEAL technique improved image quality by reducing artefacts around the brachial plexus while maintaining a high SNR and provided superior homogeneous fat suppression than FSFS sequences.

Citing Articles

Evaluation of image quality of diffusion weighted readout segmentation of long variable echo-trains MR pulse sequence for lumbosacral nerve imaging at 3T.

Abdulaal O, MacMahon P, Rainford L, Cradock A, ODriscoll D, Galligan M Quant Imaging Med Surg. 2023; 13(1):196-209.

PMID: 36620175 PMC: 9816736. DOI: 10.21037/qims-22-191.


Value of High-Resolution MRI in the Diagnosis of Brachial Plexus Injury in Infants and Young Children.

Lao Q, Jia Y, Zhao K, Liu K, Feng J Int J Gen Med. 2022; 15:5673-5680.

PMID: 35755861 PMC: 9215839. DOI: 10.2147/IJGM.S362738.


MRI of Hands with Early Rheumatoid Arthritis: Usefulness of Three-Point Dixon Sequences to Quantitatively Assess Disease Activity.

Kirchgesner T, Stoenoiu M, Durez P, Michoux N, Vande Berg B J Belg Soc Radiol. 2022; 106(1):1.

PMID: 35088027 PMC: 8757386. DOI: 10.5334/jbsr.2692.


The effects of three different contrast agents (Gd-BOPTA, Gd-DTPA, and Gd-DOTA) on brachial plexus magnetic resonance imaging.

Zhang X, Wang W, Liu T, Qi Y, Ma L Ann Transl Med. 2021; 9(4):344.

PMID: 33708971 PMC: 7944290. DOI: 10.21037/atm-21-348.


A subjective and objective comparison of tissue contrast and imaging artifacts present in routine spin echoes and in iterative decomposition of asymmetric spin echoes for soft tissue neck MRI.

Sarkar S, Hackney D, Greenman R, Vachha B, Johnson E, Nagle S Eur J Radiol. 2018; 102:202-207.

PMID: 29685536 PMC: 7453706. DOI: 10.1016/j.ejrad.2018.03.016.

References
1.
Reeder S, McKenzie C, Pineda A, Yu H, Shimakawa A, Brau A . Water-fat separation with IDEAL gradient-echo imaging. J Magn Reson Imaging. 2007; 25(3):644-52. DOI: 10.1002/jmri.20831. View

2.
Aagaard B, Maravilla K, Kliot M . MR neurography. MR imaging of peripheral nerves. Magn Reson Imaging Clin N Am. 1998; 6(1):179-94. View

3.
Tagliafico A, Tagliafico G . Fascicular ratio: a new parameter to evaluate peripheral nerve pathology on magnetic resonance imaging: a feasibility study on a 3T MRI system. Medicine (Baltimore). 2014; 93(14):e68. PMC: 4616287. DOI: 10.1097/MD.0000000000000068. View

4.
Aoki T, Yamashita Y, Oki H, Takahashi H, Hayashida Y, Saito K . Iterative decomposition of water and fat with echo asymmetry and least-squares estimation (IDEAL) of the wrist and finger at 3T: comparison with chemical shift selective fat suppression images. J Magn Reson Imaging. 2012; 37(3):733-8. DOI: 10.1002/jmri.23795. View

5.
Chang H, Juan C, Chiu H, Liu Y, Cheng C, Chiu S . Parotid fat contents in healthy subjects evaluated with iterative decomposition with echo asymmetry and least squares fat-water separation. Radiology. 2013; 267(3):918-23. DOI: 10.1148/radiol.12112599. View