Iterative Decomposition of Water and Fat with Echo Asymmetry and Least-squares Estimation (IDEAL): Application with Fast Spin-echo Imaging

Overview
Journal Magn Reson Med
Publisher Wiley
Specialty Radiology
Date 2005 Aug 11
PMID 16092103
Citations 297
Authors
Affiliations
Soon will be listed here.
Abstract

Chemical shift based methods are often used to achieve uniform water-fat separation that is insensitive to Bo inhomogeneities. Many spin-echo (SE) or fast SE (FSE) approaches acquire three echoes shifted symmetrically about the SE, creating time-dependent phase shifts caused by water-fat chemical shift. This work demonstrates that symmetrically acquired echoes cause artifacts that degrade image quality. According to theory, the noise performance of any water-fat separation method is dependent on the proportion of water and fat within a voxel, and the position of echoes relative to the SE. To address this problem, we propose a method termed "iterative decomposition of water and fat with echo asymmetric and least-squares estimation" (IDEAL). This technique combines asymmetrically acquired echoes with an iterative least-squares decomposition algorithm to maximize noise performance. Theoretical calculations predict that the optimal echo combination occurs when the relative phase of the echoes is separated by 2pi/3, with the middle echo centered at pi/2+pik (k=any integer), i.e., (-pi/6+pik, pi/2+pik, 7pi/6+pik). Only with these echo combinations can noise performance reach the maximum possible and be independent of the proportion of water and fat. Close agreement between theoretical and experimental results obtained from an oil-water phantom was observed, demonstrating that the iterative least-squares decomposition method is an efficient estimator.

Citing Articles

Unlocking the Potential of Chest MRI: Strategies for Establishing a Successful Practice.

Kim K, Kim K, Lee J, Jeong Y J Korean Soc Radiol. 2025; 86(1):83-104.

PMID: 39958489 PMC: 11822286. DOI: 10.3348/jksr.2024.0056.


Concurrent water T and fat fraction mapping of the breast using the radial gradient and spin echo (RADGRASE) pulse sequence.

Hagio T, Galons J, Roe D, Marron M, Thomson C, Thompson P Magn Reson Imaging. 2025; 118:110355.

PMID: 39921152 PMC: 11890947. DOI: 10.1016/j.mri.2025.110355.


Spiral cardiac quantitative susceptibility mapping for differential cardiac chamber oxygenation-Initial validation in relation to invasive blood sampling.

Li J, Villar-Calle P, Chiu C, Reza M, Narula N, Li C Magn Reson Med. 2024; 93(5):2029-2039.

PMID: 39641910 PMC: 11893258. DOI: 10.1002/mrm.30393.


Spectrally selective and interleaved water imaging and fat imaging (siWIFI).

Shin S, Tang Q, Carl M, Athertya J, Suprana A, Ma Y Magn Reson Med. 2024; 93(4):1556-1567.

PMID: 39533797 PMC: 11785484. DOI: 10.1002/mrm.30366.


Mapping the amplitude and phase of dissolved Xe red blood cell signal oscillations with keyhole spectroscopic lung imaging.

Pilgrim-Morris J, Collier G, Takigawa M, Strickland S, Thompson R, Norquay G Magn Reson Med. 2024; 93(2):584-596.

PMID: 39423219 PMC: 11604899. DOI: 10.1002/mrm.30296.