» Articles » PMID: 26209339

Accuracy Evaluation of CAD/CAM Generated Splints in Orthognathic Surgery: a Cadaveric Study

Overview
Journal Head Face Med
Publisher Biomed Central
Date 2015 Jul 26
PMID 26209339
Citations 18
Authors
Affiliations
Soon will be listed here.
Abstract

Introduction: To evaluate the accuracy of CAD/CAM generated splints in orthognathic surgery by comparing planned versus actual post-operative 3D images.

Methods: Specific planning software (SimPlant(®) OMS Standalone 14.0) was used to perform a 3D virtual Le Fort I osteotomy in 10 fresh human cadaver heads. Stereolithographic splints were then generated and used during the surgical procedure to reposition the maxilla according to the planned position. Pre-operative planned and postoperative 3D CT scan images were fused and imported to dedicated software (MATLAB(®)) 7.11.) for calculating the translational and rotational (pitch, roll and yaw) differences between the two 3D images. Geometrical accuracy was estimated using the Root Mean Square Deviations (RMSD) and lower and upper limits of accuracy were computed using the Bland & Altman method, with 95 % confidence intervals around the limits. The accuracy cutoff was set at +/- 2 mm for translational and ≤ 4° for rotational measurements.

Results: Overall accuracy between the two 3D images was within the accuracy cutoff for all values except for the antero-posterior positioning of the maxilla (2.17 mm). The translational and rotational differences due to the splint were all within the accuracy cutoff. However, the width of the limits of agreement (range between lower and upper limits) showed that rotational differences could be particularly large.

Conclusion: This study demonstrated that maxillary repositioning can be accurately approximated and thus predicted by specific computational planning and CAD/CAM generated splints in orthognathic surgery. Further study should focus on the risk factors for inaccurate prediction.

Citing Articles

Does mandible ramus height asymmetry affect postoperative skeletal stability in orthognathic surgery patients?.

Cha J, Park K, Ryu J, Jung S, Park H, Oh H Maxillofac Plast Reconstr Surg. 2024; 46(1):32.

PMID: 39222303 PMC: 11368883. DOI: 10.1186/s40902-024-00442-9.


Fully automated landmarking and facial segmentation on 3D photographs.

Berends B, Bielevelt F, Schreurs R, Vinayahalingam S, Maal T, de Jong G Sci Rep. 2024; 14(1):6463.

PMID: 38499700 PMC: 10948387. DOI: 10.1038/s41598-024-56956-9.


[Mandibular condyle localization in orthognathic surgery based on mandibular movement trajectory and its preliminary accuracy verification].

Xu X, Wu L, Song F, Li Z, Zhang Y, Liu X Beijing Da Xue Xue Bao Yi Xue Ban. 2024; 56(1):57-65.

PMID: 38318897 PMC: 10845196.


Is there a difference in surgical accuracy following bimaxillary surgery between cleft and non-cleft patients?.

Beek D, Visser D, Chen Y, Baan F, Nienhuijs M, Xi T Clin Oral Investig. 2024; 28(1):112.

PMID: 38265487 PMC: 10808377. DOI: 10.1007/s00784-024-05517-5.


Accuracy of maxillary positioning using computer-designed and manufactured occlusal splints or patient-specific implants in orthognathic surgery.

Malenova Y, Ortner F, Liokatis P, Haidari S, Troltzsch M, Fegg F Clin Oral Investig. 2023; 27(9):5063-5072.

PMID: 37382718 PMC: 10492762. DOI: 10.1007/s00784-023-05125-9.


References
1.
Hsu S, Gateno J, Bell R, Hirsch D, Markiewicz M, Teichgraeber J . Accuracy of a computer-aided surgical simulation protocol for orthognathic surgery: a prospective multicenter study. J Oral Maxillofac Surg. 2012; 71(1):128-42. PMC: 3443525. DOI: 10.1016/j.joms.2012.03.027. View

2.
Bouchard C, Landry P . Precision of maxillary repositioning during orthognathic surgery: a prospective study. Int J Oral Maxillofac Surg. 2012; 42(5):592-6. DOI: 10.1016/j.ijom.2012.10.034. View

3.
Polley J, Figueroa A . Orthognathic positioning system: intraoperative system to transfer virtual surgical plan to operating field during orthognathic surgery. J Oral Maxillofac Surg. 2013; 71(5):911-20. DOI: 10.1016/j.joms.2012.11.004. View

4.
Schendel S, Jacobson R, Khalessi S . 3-dimensional facial simulation in orthognathic surgery: is it accurate?. J Oral Maxillofac Surg. 2013; 71(8):1406-14. DOI: 10.1016/j.joms.2013.02.010. View

5.
Schneider M, Tzscharnke O, Pilling E, Lauer G, Eckelt U . Comparison of the predicted surgical results following virtual planning with those actually achieved following bimaxillary operation of dysgnathia. J Craniomaxillofac Surg. 2005; 33(1):8-12. DOI: 10.1016/j.jcms.2004.05.010. View