» Articles » PMID: 26048817

Gas Phase Ion Chemistry of an Ion Mobility Spectrometry Based Explosive Trace Detector Elucidated by Tandem Mass Spectrometry

Overview
Journal Talanta
Publisher Elsevier
Specialty Chemistry
Date 2015 Jun 7
PMID 26048817
Citations 7
Authors
Affiliations
Soon will be listed here.
Abstract

The gas phase ion chemistry for an ion mobility spectrometer (IMS) based explosive detector has been elucidated using tandem mass spectrometry. The IMS system, which is operated with hexachloroethane and isobutyramide reagent gases and an ion shutter type gating scheme, is connected to the atmospheric pressure interface of a triple quadrupole mass spectrometer (MS/MS). Product ion masses, daughter ion masses, and reduced mobility values for a collection of nitro, nitrate, and peroxide explosives measured with the IMS/MS/MS instrument are reported. The mass and mobility data together with targeted isotopic labeling experiments and information about sample composition and reaction environment are leveraged to propose molecular formulas, structures, and ionization pathways for the various product ions. The major product ions are identified as [DNT-H](-) for DNT, [TNT-H](-) for TNT, [RDX+Cl](-) and [RDX+NO2](-) for RDX, [HMX+Cl](-) and [HMX+NO2](-) for HMX, [NO3](-) for EGDN, [NG+Cl](-) and [NG+NO3](-) for NG, [PETN+Cl](-) and [PETN+NO3](-) for PETN, [HNO3+NO3](-) for NH4NO3, [NO2](-) for DMNB, [HMTD-NC3H6O3+H+Cl](-) and [HMTD+H-CH2O-H2O2](+) for HMTD, and [(CH3)3CO2](+) for TATP. In general, the product ions identified for the IMS system studied here are consistent with the product ions reported previously for an ion trap mobility spectrometer (ITMS) based explosive trace detector, which is operated with dichloromethane and ammonia reagent gases and an ion trap type gating scheme. Differences between the explosive trace detectors include the [NG+Cl](-) and [PETN+Cl](-) product ions being major ions in the IMS system compared to minor ions in the ITMS system as well as the major product ion for TATP being [(CH3)3CO2](+) for the IMS system and [(CH3)2CNH2](+) for the ITMS system.

Citing Articles

Isomeric Speciation of Bisbenzoxazine Intermediates by Ion Spectroscopy and Ion Mobility Mass Spectrometry.

Ribeiro F, Silva-Oliveira D, Cervi G, Koyanagui E, Correra T ACS Omega. 2024; 9(39):40932-40940.

PMID: 39372032 PMC: 11447905. DOI: 10.1021/acsomega.4c06205.


Laser Desorption of Explosives from the Surface of Different Real-World Materials Studied Using CCl-Dopant-Assisted Ion Mobility Spectrometry.

Matas E, Petrik M, Sabo M, Matejcik S Molecules. 2024; 29(18).

PMID: 39339477 PMC: 11433934. DOI: 10.3390/molecules29184482.


Time-Resolved Ion Mobility Spectrometry with a Stop Flow Confined Volume Reaction Region.

Anttalainen O, Karjalainen M, Lattouf E, Hecht O, Vanninen P, Hakulinen H Anal Chem. 2024; 96(25):10182-10192.

PMID: 38857882 PMC: 11209659. DOI: 10.1021/acs.analchem.4c00434.


Flexible Drift Tube for High Resolution Ion Mobility Spectrometry (Flex-DT-IMS).

Smith B, Boisdon C, Young I, Praneenararat T, Vilaivan T, Maher S Anal Chem. 2020; 92(13):9104-9112.

PMID: 32479060 PMC: 7467419. DOI: 10.1021/acs.analchem.0c01357.


Ammonia-Assisted Proton Transfer Reaction Mass Spectrometry for Detecting Triacetone Triperoxide (TATP) Explosive.

Zhang Q, Zou X, Liang Q, Wang H, Huang C, Shen C J Am Soc Mass Spectrom. 2018; 30(3):501-508.

PMID: 30511236 DOI: 10.1007/s13361-018-2108-6.