Identification of Phlebotomine Sand Flies Using One MALDI-TOF MS Reference Database and Two Mass Spectrometer Systems
Overview
Tropical Medicine
Authors
Affiliations
Background: Rapid, accurate and high-throughput identification of vector arthropods is of paramount importance in surveillance programmes that are becoming more common due to the changing geographic occurrence and extent of many arthropod-borne diseases. Protein profiling by MALDI-TOF mass spectrometry fulfils these requirements for identification, and reference databases have recently been established for several vector taxa, mostly with specimens from laboratory colonies.
Methods: We established and validated a reference database containing 20 phlebotomine sand fly (Diptera: Psychodidae, Phlebotominae) species by using specimens from colonies or field-collections that had been stored for various periods of time.
Results: Identical biomarker mass patterns ('superspectra') were obtained with colony- or field-derived specimens of the same species. In the validation study, high quality spectra (i.e. more than 30 evaluable masses) were obtained with all fresh insects from colonies, and with 55/59 insects deep-frozen (liquid nitrogen/-80 °C) for up to 25 years. In contrast, only 36/52 specimens stored in ethanol could be identified. This resulted in an overall sensitivity of 87 % (140/161); specificity was 100 %. Duration of storage impaired data counts in the high mass range, and thus cluster analyses of closely related specimens might reflect their storage conditions rather than phenotypic distinctness. A major drawback of MALDI-TOF MS is the restricted availability of in-house databases and the fact that mass spectrometers from 2 companies (Bruker, Shimadzu) are widely being used. We have analysed fingerprints of phlebotomine sand flies obtained by automatic routine procedure on a Bruker instrument by using our database and the software established on a Shimadzu system. The sensitivity with 312 specimens from 8 sand fly species from laboratory colonies when evaluating only high quality spectra was 98.3 %; the specificity was 100 %. The corresponding diagnostic values with 55 field-collected specimens from 4 species were 94.7 % and 97.4 %, respectively.
Conclusions: A centralized high-quality database (created by expert taxonomists and experienced users of mass spectrometers) that is easily amenable to customer-oriented identification services is a highly desirable resource. As shown in the present work, spectra obtained from different specimens with different instruments can be analysed using a centralized database, which should be available in the near future via an online platform in a cost-efficient manner.
Identification of termites from Gabon using MALDI-TOF MS.
Hasnaoui B, Zan Diarra A, Makouloutou-Nzassi P, Berenger J, Hamame A, Ngoubangoye B Heliyon. 2024; 10(6):e28081.
PMID: 38524549 PMC: 10957415. DOI: 10.1016/j.heliyon.2024.e28081.
Cannet A, Simon-Chane C, Histace A, Akhoundi M, Romain O, Souchaud M Sci Rep. 2023; 13(1):21389.
PMID: 38049590 PMC: 10696019. DOI: 10.1038/s41598-023-48685-2.
Lozano-Sardaneta Y, Diaz-Cruz J, Viveros-Santos V, Ibanez-Bernal S, Huerta H, Marina C PLoS One. 2023; 18(6):e0287853.
PMID: 37384618 PMC: 10309607. DOI: 10.1371/journal.pone.0287853.
A Review of Historical Phlebotominae Taxonomy (Diptera: Psychodidae).
Galati E, Rodrigues B Neotrop Entomol. 2023; 52(4):539-559.
PMID: 36897326 DOI: 10.1007/s13744-023-01030-8.
Sanchez-Juanes F, Calvo Sanchez N, Belhassen Garcia M, Lista C, Roman R, Alamo Sanz R Microorganisms. 2022; 10(11).
PMID: 36422371 PMC: 9695109. DOI: 10.3390/microorganisms10112300.