» Articles » PMID: 25953531

Perioperative Cardiovascular Monitoring of High-risk Patients: a Consensus of 12

Overview
Journal Crit Care
Specialty Critical Care
Date 2015 May 9
PMID 25953531
Citations 79
Authors
Affiliations
Soon will be listed here.
Abstract

A significant number of surgical patients are at risk of intra- or post-operative complications or both, which are associated with increased lengths of stay, costs, and mortality. Reducing these risks is important for the individual patient but also for health-care planners and managers. Insufficient tissue perfusion and cellular oxygenation due to hypovolemia, heart dysfunction or both is one of the leading causes of perioperative complications. Adequate perioperative management guided by effective and timely hemodynamic monitoring can help reduce the risk of complications and thus potentially improve outcomes. In this review, we describe the various available hemodynamic monitoring systems and how they can best be used to guide cardiovascular and fluid management in the perioperative period in high-risk surgical patients.

Citing Articles

Effect of neurally adjusted ventilator assist versus pressure support ventilation on asynchronies and cardiac function in pediatric liver transplantation.

Chiusolo F, Spinazzola G, Costa R, Franceschini A, Tortora F, Polisca F Sci Rep. 2025; 15(1):7158.

PMID: 40021754 PMC: 11871333. DOI: 10.1038/s41598-025-91590-z.


Validity of Pleth Variability Index to Predict Fluid Responsiveness in Patients Undergoing Cervical Spine Surgery in the Modified Prone Position.

Koh W, Lee D, Ro Y, Park H Medicina (Kaunas). 2025; 60(12.

PMID: 39768898 PMC: 11728039. DOI: 10.3390/medicina60122018.


Changes in central venous pressure during a fluid challenge have limited value for guiding fluid therapy.

de Oliveira P, da Silva Ramos F, Tomotani D, Machado F, de Freitas F Crit Care Sci. 2024; 36:e20240073en.

PMID: 39630827 PMC: 11634234. DOI: 10.62675/2965-2774.20240073-en.


Correlations between preoperative fluid status assessed by bioimpedance analysis and hypotension during anaesthesia induction.

Siriopol I, Grigoras I, Rusu D, Popa R, Ristescu I, Kanbay M Anaesthesiol Intensive Ther. 2024; 56(3):177-184.

PMID: 39451164 PMC: 11484485. DOI: 10.5114/ait.2024.142671.


Heart failure diagnostic accuracy, intraoperative fluid management, and postoperative acute kidney injury: a single-centre prospective observational study.

Mathis M, Ghadimi K, Benner A, Jewell E, Janda A, Joo H Br J Anaesth. 2024; 134(1):32-44.

PMID: 39389834 PMC: 11832916. DOI: 10.1016/j.bja.2024.08.020.


References
1.
Hofer C, Buhlmann S, Klaghofer R, Genoni M, Zollinger A . Pulsed dye densitometry with two different sensor types for cardiac output measurement after cardiac surgery: a comparison with the thermodilution technique. Acta Anaesthesiol Scand. 2004; 48(5):653-7. DOI: 10.1111/j.1399-6576.2004.00371.x. View

2.
Kulemann B, Timme S, Seifert G, Holzner P, Glatz T, Sick O . Intraoperative crystalloid overload leads to substantial inflammatory infiltration of intestinal anastomoses-a histomorphological analysis. Surgery. 2013; 154(3):596-603. DOI: 10.1016/j.surg.2013.04.010. View

3.
Morris C . Oesophageal Doppler monitoring, doubt and equipoise: evidence based medicine means change. Anaesthesia. 2013; 68(7):684-8. DOI: 10.1111/anae.12306. View

4.
Monnet X, Teboul J . Passive leg raising. Intensive Care Med. 2008; 34(4):659-63. DOI: 10.1007/s00134-008-0994-y. View

5.
Ball T, Culp B, Patel V, Gloyna D, Ciceri D, Culp Jr W . Comparison of the endotracheal cardiac output monitor to thermodilution in cardiac surgery patients. J Cardiothorac Vasc Anesth. 2010; 24(5):762-6. DOI: 10.1053/j.jvca.2010.04.008. View