» Articles » PMID: 25850583

ART for Head and Neck Patients: On the Difference Between VMAT and IMPT

Overview
Journal Acta Oncol
Specialty Oncology
Date 2015 Apr 9
PMID 25850583
Citations 18
Authors
Affiliations
Soon will be listed here.
Abstract

Unlabelled: Anatomical changes in the head-and-neck (H&N) region during the course of treatment can cause deteriorated dose distributions. Different replanning strategies were investigated for volumetric modulated arc therapy (VMAT) and intensity-modulated proton therapy (IMPT).

Material And Methods: For six H&N patients two repeated computed tomography (CT) and magnetic resonance (MR) (CT1/MR1 at week 2 and CT2/MR2 at week 4) scans were acquired additionally to the initial planning CT/MR. Organs-at-risk (OARs) and three targets (CTV70Gy, CTV63Gy, CTV56Gy) were delineated on MRs and transferred to respective CT data set. Simultaneously integrated boost plans were created using VMAT (two arcs) and IMPT (four beams). To assess the need of replanning the initial VMAT and IMPT plans were recalculated on repeated CTs. Furthermore, VMAT and IMPT plans were replanned on the repeated CTs. A Demon algorithm was used for deformable registration of the repeated CTs with the initial CT and utilized for dose accumulation. Total dose estimations were performed to compare ART versus standard treatment strategies.

Results: Dosimetric evaluation of recalculated plans on CT1 and CT2 showed increasing OAR doses for both, VMAT and IMPT. The target coverage of recalculated VMAT plans was considered acceptable in three cases, while for all IMPT plans it dropped. Adaptation of the treatment reduced D2% for brainstem by 6.7 Gy for VMAT and by 8 Gy for IMPT, for particular patients. These D2% reductions were reaching 9 Gy and 14 Gy for the spinal cord. ART improved target dose homogeneity, especially for protons, i.e. D2% decreased by up to 8 Gy while D98% increased by 1.2 Gy.

Conclusion: ART showed benefits for both modalities. However, as IMPT is more conformal, the magnitude of dosimetric changes was more pronounced compared to VMAT. Large anatomic variations had a severe impact on treatment plan quality for both VMAT and IMPT. ART is justified in those cases irrespective of treatment modalities.

Citing Articles

Cone beam CT-based adaptive intensity modulated proton therapy assessment using automated planning for head-and-neck cancer.

Xu Y, Jin W, Butkus M, De Ornelas M, Cyriac J, Studenski M Radiat Oncol. 2024; 19(1):13.

PMID: 38263237 PMC: 10804468. DOI: 10.1186/s13014-024-02406-9.


Daily Head and Neck Treatment Assessment for Optimal Proton Therapy Planning Robustness.

Chang L, Shaaban S, Gogineni E, Page B, Quon H, Li H Cancers (Basel). 2023; 15(14).

PMID: 37509380 PMC: 10378634. DOI: 10.3390/cancers15143719.


Large anatomical changes in head-and-neck cancers - A dosimetric comparison of online and offline adaptive proton therapy.

Bobic M, Lalonde A, Nesteruk K, Lee H, Nenoff L, Gorissen B Clin Transl Radiat Oncol. 2023; 40:100625.

PMID: 37090849 PMC: 10120292. DOI: 10.1016/j.ctro.2023.100625.


Proton Therapy in Head and Neck Cancer Treatment: State of the Problem and Development Prospects (Review).

Gordon K, Smyk D, Gulidov I Sovrem Tekhnologii Med. 2021; 13(4):70-80.

PMID: 34603766 PMC: 8482826. DOI: 10.17691/stm2021.13.4.08.


Trend analysis of the dosimetric impact of anatomical changes during proton therapy for maxillary sinus carcinoma.

Narita Y, Kato T, Ono T, Oyama S, Yamazaki Y, Ouchi H J Appl Clin Med Phys. 2021; 22(9):298-306.

PMID: 34402579 PMC: 8425936. DOI: 10.1002/acm2.13391.