» Articles » PMID: 25819787

Simultaneous Electrochemical Sensing of Thallium, Lead and Mercury Using a Novel Ionic Liquid/graphene Modified Electrode

Overview
Journal Anal Chim Acta
Publisher Elsevier
Specialty Chemistry
Date 2015 Mar 31
PMID 25819787
Citations 15
Authors
Affiliations
Soon will be listed here.
Abstract

In the present manuscript, an electrochemical sensor for the sensitive detection of Tl(+), Pb(2+) and Hg(2+) is described. A new composite electrode has been fabricated using graphene, 1-n-octylpyridinum hexafluorophosphate (OPFP), and [2,4-Cl2C6H3C(O)CHPPh3] (L), as a new synthetic phosphorus ylide. The physicochemical and electrochemical characterizations of fabricated sensor were investigated in details. The advantages of the proposed composite electrode are its ability in simultaneous electrochemical detection of Tl(+), Pb(2+) and Hg(2+) with good selectivity, stability and no need for separating of the three species from complex mixtures prior to electrochemical measurements. The analytical performance of the proposed electrode was examined using square wave voltammetry. Tl(+), Pb(2+) and Hg(2+) can be determined in linear ranges from 1.25×10(-9) to 2.00×10(-7) mol L(-1). Low detection limits of 3.57×10(-10) mol L(-1) for Tl(+), 4.50×10(-10) mol L(-1) for Pb(2+) and 3.86×10(-10) mol L(-1) for Hg(2+) were achieved. Finally, the proposed electrochemical sensor was applied to detect trace analyte ions in various water and soil samples with satisfactory results.

Citing Articles

Graphene-Oxide Peptide-Containing Materials for Biomedical Applications.

Gostaviceanu A, Gavrilas S, Copolovici L, Copolovici D Int J Mol Sci. 2024; 25(18).

PMID: 39337659 PMC: 11432502. DOI: 10.3390/ijms251810174.


Electrochemical Sensors for Heavy Metal Ion Detection in Aqueous Medium: A Systematic Review.

Sulthana S, Iqbal U, Suseela S, Anbazhagan R, Chinthaginjala R, Chitathuru D ACS Omega. 2024; 9(24):25493-25512.

PMID: 38911761 PMC: 11190924. DOI: 10.1021/acsomega.4c00933.


A Review on Recent Trends and Future Developments in Electrochemical Sensing.

Singh R, Gupta R, Bansal D, Bhateria R, Sharma M ACS Omega. 2024; 9(7):7336-7356.

PMID: 38405479 PMC: 10882602. DOI: 10.1021/acsomega.3c08060.


Anodic Stripping Voltammetric Procedure of Thallium(I) Determination by Means of a Bismuth-Plated Gold-Based Microelectrode Array.

Korolczuk M, Ochab M, Geca I Sensors (Basel). 2024; 24(4).

PMID: 38400364 PMC: 10892365. DOI: 10.3390/s24041206.


A non-enzymatic electrochemical sensor based on nitrogen-doped mesoporous carbon@hydroxyl-functionalized ionic liquid composites modified electrode for the detection of fenitrothion.

Liu X, Li Y, Qiao W, Chang M, Li Y RSC Adv. 2023; 13(19):13030-13039.

PMID: 37124009 PMC: 10133836. DOI: 10.1039/d3ra01011b.