Pneumothorax Resulting from Subclavian Puncture: a Complication of Permanent Pacemaker Lead Implantation

Overview
Journal Neth Heart J
Date 2015 Feb 20
PMID 25696306
Citations 10
Authors
Affiliations
Soon will be listed here.
Abstract

Pneumothorax is a mild complication during pacemaker lead implantation using the subclavian puncture technique. We report on five-year experience in 433 pacemaker lead implantation procedures in 379 patients. The cephalic vein route was solely used in twelve patients. Three procedures were performed over time in four patients and one patient needed four repetitive punctures for pacemaker lead implantation and replacement. Thus 421 punctures were carried out in 367 patients. Eleven case of pneumothorax were observed: in eight patients (1.9%) a partial pneumothorax occurred and in three patients (0.7%) the pneumothorax was nearly complete. In the latter patients a chest tube was inserted and hospital admission was prolonged for 3, 6 and 6 days, respectively. Old age with a corresponding abnormality in the form of chest deformation were predominantly found in the patients with this type of complication.

Citing Articles

Case report: A rare complication after the implantation of a cardiac implantable electronic device: Contralateral pneumothorax with pneumopericardium and pneumomediastinum.

Lo S, Chen J Front Cardiovasc Med. 2022; 9:938735.

PMID: 36061532 PMC: 9433779. DOI: 10.3389/fcvm.2022.938735.


Long-term in vivo operation of implanted cardiac nanogenerators in swine.

Li J, Hacker T, Wei H, Long Y, Yang F, Ni D Nano Energy. 2021; 90(Pt A).

PMID: 34737918 PMC: 8562697. DOI: 10.1016/j.nanoen.2021.106507.


Bilateral Pneumothorax Complicating Pacemaker Implantation, due to Puncture of the Left Subclavian Vein and Electrode Perforation of the Right Atrium.

Olesen L Cureus. 2020; 12(11):e11302.

PMID: 33282579 PMC: 7716385. DOI: 10.7759/cureus.11302.


Cardiac Implantable Electronic Miniaturized and Micro Devices.

Rav Acha M, Soifer E, Hasin T Micromachines (Basel). 2020; 11(10).

PMID: 33003460 PMC: 7600795. DOI: 10.3390/mi11100902.


Access times for supraclavicular and infraclavicular approaches of subclavian vein catheterization in pacemaker insertion.

Javed N, Malik J Int J Health Sci (Qassim). 2020; 14(3):14-17.

PMID: 32536844 PMC: 7269626.


References
1.
Furman S . Venous cutdown for pacemaker implantation. Ann Thorac Surg. 1986; 41(4):438-9. DOI: 10.1016/s0003-4975(10)62705-1. View

2.
Kiviniemi M, Pirnes M, Eranen H, Kettunen R, Hartikainen J . Complications related to permanent pacemaker therapy. Pacing Clin Electrophysiol. 1999; 22(5):711-20. DOI: 10.1111/j.1540-8159.1999.tb00534.x. View

3.
Fyke 3rd F . Doppler guided extrathoracic introducer insertion. Pacing Clin Electrophysiol. 1995; 18(5 Pt 1):1017-21. DOI: 10.1111/j.1540-8159.1995.tb04742.x. View

4.
Youmans Jr C, DERRICK J, Wallace J . Considerations of complications of permanent transvenous pacemakers. Am J Surg. 1967; 114(5):704-10. DOI: 10.1016/0002-9610(67)90133-x. View

5.
Kessinger J, Holter A, Geha A . Implantation of permanent transvenous pacemaker via subclavian vein. Arch Surg. 1982; 117(8):1105-7. DOI: 10.1001/archsurg.1982.01380320087023. View