A Novel Visual Sputum Suctioning System is Useful for Endotracheal Suctioning in a Dog Model
Overview
Affiliations
Objective: This study is to test the effectiveness of fiber-optic-guided endotracheal suction catheter (visual sputum suctioning system or VSSS) in dog models.
Methods: Dog sputum models were established by administering dimethoate emulsifiable. Twenty-seven intubated dogs were equally randomized into three groups of conventional suctioning (CS) group, VSSS with no supplemental oxygen (VSSS) group and VSSS with 100% oxygen (VSSS/O2) group. The suctioning efficiency, vital signs and tracheal wall injury were assessed.
Results: The VSSS/O2 (8.6 ± 0.7g) and VSSS groups (8.5 ± 0.9 g) collected significantly more sputum than the CS group (5.9 ± 0.8 g) (P < 0.05 for VSSS/O2 group versus CS group; P < 0.05 for VSSS group versus CS group). Immediately after suctioning, the arterial partial pressure of oxygen (PaO2 ) of VSSS/O2 group was significantly higher than that of the VSSS group or the CS group (both P < 0.05), and 5 min after suction the PaO2 , the mean arterial pressure (MAP) and heart rate (HR) in all groups returned to the baseline (p = 0.54, P = 0.67, P = 0.11, respectively). Moreover, in the VSSS/O2 and VSSS groups all the three variables were higher than the CS group at 5 min after suctioning (P < 0.01, P = 0.03; P = 0.02, P < 0.01; P = 0.02, P = 0.01 respectively).
Conclusions: Visual sputum suctioning system collected more sputum and caused less tracheal mucosa damage than conventional suctioning.
Novel Visual Nasogastric Tube Insertion System: A Feasibility and Efficiency Study in a Manikin.
Li Q, Xie J, Wu J, Guo R, Ma W, Xu G Gastroenterol Res Pract. 2016; 2016:7532172.
PMID: 27994620 PMC: 5141553. DOI: 10.1155/2016/7532172.