» Articles » PMID: 16033592

Requirement for 100% Oxygen Before and After Closed Suction

Overview
Journal J Adv Nurs
Specialty Nursing
Date 2005 Jul 22
PMID 16033592
Citations 8
Authors
Affiliations
Soon will be listed here.
Abstract

Aim: This paper reports an experimental study to determine whether giving 100% oxygen for 1 minute before and after closed suctioning is required.

Background: Some studies suggest that patients receiving closed suction do not require preoxygenation to minimize desaturation.

Methods: The study was conducted in 2002, with 30 patients receiving mechanical ventilation who had various positive end-expiratory levels. Two suctioning methods were used for each patient: one involving administration of 100% oxygen for 1 minute before and after suctioning and the other without hyperoxygenation. Samples of arterial blood gases were taken before and after suctioning. Heart rate, arterial oxygen saturation and mean arterial pressure measures were documented before, immediately after, 30 and 60 seconds after suctioning.

Results: Levels of partial oxygen pressure, arterial oxygen saturation and mean arterial pressure were significantly higher in patients who received 100% oxygen for 1 minute before and after suction, whereas partial carbon dioxide pressure and heart rate were similar in the two groups.

Conclusions: In patients who did not receive 100% oxygen before and after closed suctioning, no significant falls in partial oxygen pressure and oxygen saturation were seen. A small number of patients were hypoxaemic before suctioning, and not [corrected] giving 100% oxygen might be deleterious for this category.

Citing Articles

Comparison of the effects of open and closed aspiration on end-expiratory lung volume in acute respiratory distress syndrome.

Yildirim S, Saygili S, Sunecli O, Kirakli C Korean J Anesthesiol. 2023; 77(1):115-121.

PMID: 37211764 PMC: 10834727. DOI: 10.4097/kja.23194.


The practice of intensive care nurses using the closed suctioning system: An observational study.

Haghighat S, Yazdannik A Iran J Nurs Midwifery Res. 2015; 20(5):619-25.

PMID: 26457102 PMC: 4598911. DOI: 10.4103/1735-9066.164509.


A novel visual sputum suctioning system is useful for endotracheal suctioning in a dog model.

Liu X, Deng H, Huang Z, Yan B, Lv J, Wu J Int J Clin Exp Med. 2015; 7(12):4819-27.

PMID: 25663978 PMC: 4307425.


The effect of the open and closed system suctions on cardiopulmonary parameters: time and costs in patients under mechanical ventilation.

Afshari A, Safari M, Oshvandi K, Soltanian A Nurs Midwifery Stud. 2014; 3(2):e14097.

PMID: 25414899 PMC: 4228526.


Comparing two levels of closed system suction pressure in ICU patients: Evaluating the relative safety of higher values of suction pressure.

Yazdannik A, Haghighat S, Saghaei M, Eghbali M Iran J Nurs Midwifery Res. 2013; 18(2):117-22.

PMID: 23983740 PMC: 3748566.