» Articles » PMID: 25486611

Semi-automated Selection of Cryo-EM Particles in RELION-1.3

Overview
Journal J Struct Biol
Date 2014 Dec 9
PMID 25486611
Citations 208
Authors
Affiliations
Soon will be listed here.
Abstract

The selection of particles suitable for high-resolution cryo-EM structure determination from noisy micrographs may represent a tedious and time-consuming step. Here, a semi-automated particle selection procedure is presented that has been implemented within the open-source software RELION. At the heart of the procedure lies a fully CTF-corrected template-based picking algorithm, which is supplemented by a fast sorting algorithm and reference-free 2D class averaging to remove false positives. With only limited user-interaction, the proposed procedure yields results that are comparable to manual particle selection. Together with an improved graphical user interface, these developments further contribute to turning RELION from a stand-alone refinement program into a convenient image processing pipeline for the entire single-particle approach.

Citing Articles

AI-based methods for biomolecular structure modeling for Cryo-EM.

Farheen F, Terashi G, Zhu H, Kihara D Curr Opin Struct Biol. 2025; 90:102989.

PMID: 39864242 PMC: 11793015. DOI: 10.1016/j.sbi.2025.102989.


Deciphering the molecular basis of lipoprotein recognition and transport by LolCDE.

Qiao W, Shen C, Chen Y, Chang S, Wang X, Yang L Signal Transduct Target Ther. 2024; 9(1):354.

PMID: 39725716 PMC: 11671585. DOI: 10.1038/s41392-024-02067-w.


RNA sample optimization for cryo-EM analysis.

Chen X, Wang L, Xie J, Nowak J, Luo B, Zhang C Nat Protoc. 2024; .

PMID: 39548288 DOI: 10.1038/s41596-024-01072-1.


REliable PIcking by Consensus (REPIC): a consensus methodology for harnessing multiple cryo-EM particle pickers.

Cameron C, Seager S, Sigworth F, Tagare H, Gerstein M Commun Biol. 2024; 7(1):1421.

PMID: 39482410 PMC: 11528043. DOI: 10.1038/s42003-024-07045-0.


Structural insights into the mechanotransducing mechanism of FtsEX in cell division.

Chen Y, Guo D, Wang X, Zhang C, Chen Y, Luo Q MedComm (2020). 2024; 5(11):e688.

PMID: 39434966 PMC: 11491553. DOI: 10.1002/mco2.688.


References
1.
Amunts A, Brown A, Bai X, Llacer J, Hussain T, Emsley P . Structure of the yeast mitochondrial large ribosomal subunit. Science. 2014; 343(6178):1485-1489. PMC: 4046073. DOI: 10.1126/science.1249410. View

2.
Wong W, Bai X, Brown A, Fernandez I, Hanssen E, Condron M . Cryo-EM structure of the Plasmodium falciparum 80S ribosome bound to the anti-protozoan drug emetine. Elife. 2014; 3. PMC: 4086275. DOI: 10.7554/eLife.03080. View

3.
Mindell J, Grigorieff N . Accurate determination of local defocus and specimen tilt in electron microscopy. J Struct Biol. 2003; 142(3):334-47. DOI: 10.1016/s1047-8477(03)00069-8. View

4.
Nicholson W, Glaeser R . Review: automatic particle detection in electron microscopy. J Struct Biol. 2001; 133(2-3):90-101. DOI: 10.1006/jsbi.2001.4348. View

5.
Fernandez I, Bai X, Hussain T, Kelley A, Lorsch J, Ramakrishnan V . Molecular architecture of a eukaryotic translational initiation complex. Science. 2013; 342(6160):1240585. PMC: 3836175. DOI: 10.1126/science.1240585. View