» Articles » PMID: 25459235

Comparisons of Prediction Equations for Estimating Energy Expenditure in Youth

Overview
Journal J Sci Med Sport
Specialty Orthopedics
Date 2014 Dec 3
PMID 25459235
Citations 14
Authors
Affiliations
Soon will be listed here.
Abstract

Objectives: The purpose of this study was to compare the validity of Actigraph 2-regression models (2RM) and 1-regression models (1RM) for estimation of EE in children.

Design: The study used a cross-sectional design with criterion estimates from a metabolic cart.

Methods: A total of 59 children (7-13yrs) performed 12 activities (randomly selected from a set of 24 activities) for 5min each, while being concurrently measured with an Actigraph GT3X and indirect calorimetry. METRMR (MET considering one's resting metabolic rate) for the GT3X was estimated applying 2RM with vector magnitude (VM2RM) and vertical axis (VA2RM), and four standard 1RMs. The validity of the 2RMs and 1RMs was evaluated using 95% equivalence testing and mean absolute percent error (MAPE).

Results: For the group-level comparison, equivalence testing revealed that the 90% confidence intervals for all 2RMs and 1RMs were outside of the equivalence zone (range: 3.63, 4.43) for indirect calorimetry. When comparing the individual activities, VM2RM produced smaller MAPEs (range: 14.5-45.3%) than VA2RM (range, 15.5-58.1%) and 1RMs (range, 14.5-75.1%) for most of the light and moderate activities.

Conclusions: None of the 2RMs and 1RMs were equivalent to indirect calorimetry. The 2RMs showed smaller individual-level errors than the 1RMs.

Citing Articles

Comparison of raw accelerometry data from ActiGraph, Apple Watch, Garmin, and Fitbit using a mechanical shaker table.

White 3rd J, Finnegan O, Tindall N, Nelakuditi S, Brown 3rd D, Pate R PLoS One. 2024; 19(3):e0286898.

PMID: 38551940 PMC: 10980217. DOI: 10.1371/journal.pone.0286898.


Estimating Physical Activity and Sleep using the Combination of Movement and Heart Rate: A Systematic Review and Meta-Analysis.

White 3rd J, Pfledderer C, Kinard P, Beets M, VON Klinggraeff L, Armstrong B Int J Exerc Sci. 2024; 16(7):1514-1539.

PMID: 38287938 PMC: 10824314. DOI: 10.70252/VNKN6618.


Validity of Actigraph for Measuring Energy Expenditure in Healthy Adults: A Systematic Review and Meta-Analysis.

Wu W, Yu H, Tai W, Zhang R, Hao W Sensors (Basel). 2023; 23(20).

PMID: 37896640 PMC: 10610851. DOI: 10.3390/s23208545.


A comparison of accelerometer cut-points for measuring physical activity and sedentary time in adolescents with Down syndrome.

Forseth B, Carlson J, Willis E, Helsel B, Ptomey L Res Dev Disabil. 2021; 120:104126.

PMID: 34837754 PMC: 8724392. DOI: 10.1016/j.ridd.2021.104126.


The Validity of MotionSense HRV in Estimating Sedentary Behavior and Physical Activity under Free-Living and Simulated Activity Settings.

Kwon S, Wan N, Burns R, Brusseau T, Kim Y, Kumar S Sensors (Basel). 2021; 21(4).

PMID: 33670507 PMC: 7922785. DOI: 10.3390/s21041411.


References
1.
Firouzbakhsh S, Mathis R, Dorchester W, Oseas R, Groncy P, Grant K . Measured resting energy expenditure in children. J Pediatr Gastroenterol Nutr. 1993; 16(2):136-42. DOI: 10.1097/00005176-199302000-00007. View

2.
Hodges L, Brodie D, Bromley P . Validity and reliability of selected commercially available metabolic analyzer systems. Scand J Med Sci Sports. 2005; 15(5):271-9. DOI: 10.1111/j.1600-0838.2005.00477.x. View

3.
Treuth M, Schmitz K, Catellier D, McMurray R, Murray D, Almeida M . Defining accelerometer thresholds for activity intensities in adolescent girls. Med Sci Sports Exerc. 2004; 36(7):1259-66. PMC: 2423321. View

4.
Rothney M, Brychta R, Meade N, Chen K, Buchowski M . Validation of the ActiGraph two-regression model for predicting energy expenditure. Med Sci Sports Exerc. 2010; 42(9):1785-92. PMC: 2919650. DOI: 10.1249/MSS.0b013e3181d5a984. View

5.
Trost S, Ward D, Moorehead S, Watson P, Riner W, Burke J . Validity of the computer science and applications (CSA) activity monitor in children. Med Sci Sports Exerc. 1998; 30(4):629-33. DOI: 10.1097/00005768-199804000-00023. View