(19)F MRI is emerging as a new imaging technique for cell tracking. It is particularly attractive because of its potential for direct and precise cell quantification. The most important challenge towards in vivo applications is the sensitivity of the technique, i.e. the detection limit in a reasonable imaging time. Optimal sensitivity can be achieved with dedicated (19)F compounds together with specifically adapted hardware and acquisition methods. In this paper we introduce the (19)F MRI technique focusing on these key sensitivity issues and review the state-of-the-art of (19)F MRI and developments towards its clinical use. We calculate (19)F detection limits reported in preclinical cell and clinical (19)F drug studies in terms of tissue concentration in a 1 cm(3) voxel, as an alternate way to compare detection limits. We estimate that a tissue concentration of a few millimoles per litre (mM) of (19)F is required for a human study at a resolution of 1 cm(3).

Citing Articles

Polymeric (Poly(lactic--glycolic acid)) Particles Entrapping Perfluorocarbons Are Stable for a Minimum of Six Years.

Mali A, Nayak N, van Doesburg J, Fokkink R, van Riessen K, de Kruijf R ACS Omega. 2025; 10(7):6768-6779.

PMID: 40028150 PMC: 11865981. DOI: 10.1021/acsomega.4c08663.


Feasibility and optimization ofF MRI on a clinical 3T with a large field-of-view torso coil.

Lechuga L, Cho M, Vail D, Captini C, Fain S, Begovatz P Phys Med Biol. 2024; 69(12.

PMID: 38759675 PMC: 11149172. DOI: 10.1088/1361-6560/ad4d50.


How to 19F MRI: applications, technique, and getting started.

Maxouri O, Bodalal Z, Daal M, Rostami S, Rodriguez I, Akkari L BJR Open. 2023; 5(1):20230019.

PMID: 37953866 PMC: 10636348. DOI: 10.1259/bjro.20230019.


Design of triphasic poly(lactic--glycolic acid) nanoparticles containing a perfluorocarbon phase for biomedical applications.

Swider E, Staal A, van Riessen N, Jacobs L, White P, Fokkink R RSC Adv. 2022; 8(12):6460-6470.

PMID: 35540375 PMC: 9078287. DOI: 10.1039/c7ra13062g.


Nanotechnology as a Versatile Tool for F-MRI Agent's Formulation: A Glimpse into the Use of Perfluorinated and Fluorinated Compounds in Nanoparticles.

Joseph J, Gigliobianco M, Mahdavi Firouzabadi B, Censi R, Di Martino P Pharmaceutics. 2022; 14(2).

PMID: 35214114 PMC: 8874484. DOI: 10.3390/pharmaceutics14020382.


References
1.
Economopoulos V, Chen Y, McFadden C, Foster P . MRI detection of nonproliferative tumor cells in lymph node metastases using iron oxide particles in a mouse model of breast cancer. Transl Oncol. 2013; 6(3):347-54. PMC: 3660804. DOI: 10.1593/tlo.13121. View

2.
Chen W, Takahashi A, Han E . Quantitative T(1)(ρ) imaging using phase cycling for B0 and B1 field inhomogeneity compensation. Magn Reson Imaging. 2011; 29(5):608-19. DOI: 10.1016/j.mri.2011.02.002. View

3.
de Vries I, Lesterhuis W, Barentsz J, Verdijk P, van Krieken J, Boerman O . Magnetic resonance tracking of dendritic cells in melanoma patients for monitoring of cellular therapy. Nat Biotechnol. 2005; 23(11):1407-13. DOI: 10.1038/nbt1154. View

4.
Bonetto F, Srinivas M, Heerschap A, Mailliard R, Ahrens E, Figdor C . A novel (19)F agent for detection and quantification of human dendritic cells using magnetic resonance imaging. Int J Cancer. 2010; 129(2):365-73. PMC: 3085097. DOI: 10.1002/ijc.25672. View

5.
Weise G, Basse-Luesebrink T, Wessig C, Jakob P, Stoll G . In vivo imaging of inflammation in the peripheral nervous system by (19)F MRI. Exp Neurol. 2011; 229(2):494-501. DOI: 10.1016/j.expneurol.2011.03.020. View