Accuracy and Precision of Visual Stimulus Timing in PsychoPy: No Timing Errors in Standard Usage
Overview
Authors
Affiliations
In a recent report published in PLoS ONE, we found that the performance of PsychoPy degraded with very short timing intervals, suggesting that it might not be perfectly suitable for experiments requiring the presentation of very brief stimuli. The present study aims to provide an updated performance assessment for the most recent version of PsychoPy (v1.80) under different hardware/software conditions. Overall, the results show that PsychoPy can achieve high levels of precision and accuracy in the presentation of brief visual stimuli. Although occasional timing errors were found in very demanding benchmarking tests, there is no reason to think that they can pose any problem for standard experiments developed by researchers.
Katsumata R, Hosokawa T, Kamada T Cureus. 2024; 15(12):e49877.
PMID: 38170031 PMC: 10761299. DOI: 10.7759/cureus.49877.
Katsumata R, Hosokawa T, Manabe N, Mori H, Wani K, Ishii K J Gastroenterol. 2023; 58(12):1178-1187.
PMID: 37572136 PMC: 10657794. DOI: 10.1007/s00535-023-02031-5.
Liu Z, Chen Y Behav Res Methods. 2022; 55(7):3805-3819.
PMID: 36253597 DOI: 10.3758/s13428-022-01990-6.
Time changes: Timing contexts support event segmentation in associative memory.
van de Ven V, Jackels M, de Weerd P Psychon Bull Rev. 2021; 29(2):568-580.
PMID: 34647275 PMC: 9038903. DOI: 10.3758/s13423-021-02000-0.
Karch S, Krause D, Lehnert K, Konrad J, Haller D, Rauchmann B Eur Arch Psychiatry Clin Neurosci. 2021; 272(4):557-569.
PMID: 34622344 PMC: 9095551. DOI: 10.1007/s00406-021-01336-x.