» Articles » PMID: 25331897

Volta Potential Phase Plate for In-focus Phase Contrast Transmission Electron Microscopy

Overview
Specialty Science
Date 2014 Oct 22
PMID 25331897
Citations 176
Authors
Affiliations
Soon will be listed here.
Abstract

We describe a phase plate for transmission electron microscopy taking advantage of a hitherto-unknown phenomenon, namely a beam-induced Volta potential on the surface of a continuous thin film. The Volta potential is negative, indicating that it is not caused by beam-induced electrostatic charging. The film must be heated to ∼ 200 °C to prevent contamination and enable the Volta potential effect. The phase shift is created "on the fly" by the central diffraction beam eliminating the need for precise phase plate alignment. Images acquired with the Volta phase plate (VPP) show higher contrast and unlike Zernike phase plate images no fringing artifacts. Following installation into the microscope, the VPP has an initial settling time of about a week after which the phase shift behavior becomes stable. The VPP has a long service life and has been used for more than 6 mo without noticeable degradation in performance. The mechanism underlying the VPP is the same as the one responsible for the degradation over time of the performance of thin-film Zernike phase plates, but in the VPP it is used in a constructive way. The exact physics and/or chemistry behind the process causing the Volta potential are not fully understood, but experimental evidence suggests that radiation-induced surface modification combined with a chemical equilibrium between the surface and residual gases in the vacuum play an important role.

Citing Articles

Centromeric chromatin clearings demarcate the site of kinetochore formation.

Kixmoeller K, Tarasovetc E, Mer E, Chang Y, Black B Cell. 2025; 188(5):1280-1296.e19.

PMID: 39855195 PMC: 11890969. DOI: 10.1016/j.cell.2024.12.025.


Cryo-electron tomography of eel sperm flagella reveals a molecular "minimum system" for motile cilia.

Schrad J, Fu G, Hable W, Tayar A, Oliveira K, Nicastro D Mol Biol Cell. 2024; 36(2):ar15.

PMID: 39661459 PMC: 11809310. DOI: 10.1091/mbc.E24-08-0351.


Visualizing the virus world inside the cell by cryo-electron tomography.

Zhou Q, Lok S J Virol. 2024; 98(12):e0108523.

PMID: 39494908 PMC: 11650999. DOI: 10.1128/jvi.01085-23.


ARL3 GTPases facilitate ODA16 unloading from IFT in motile cilia.

Huang Y, Dong X, Sun S, Lim T, Lin Q, He C Sci Adv. 2024; 10(36):eadq2950.

PMID: 39231220 PMC: 11373600. DOI: 10.1126/sciadv.adq2950.


Cryo-EM phase-plate images reveal unexpected levels of apparent specimen damage.

Remis J, Petrov P, Zhang J, Axelrod J, Cheng H, Sandhaus S bioRxiv. 2024; .

PMID: 39149370 PMC: 11326166. DOI: 10.1101/2024.08.04.606536.


References
1.
Danev R, Kanamaru S, Marko M, Nagayama K . Zernike phase contrast cryo-electron tomography. J Struct Biol. 2010; 171(2):174-81. DOI: 10.1016/j.jsb.2010.03.013. View

2.
Danev R, Nagayama K . Optimizing the phase shift and the cut-on periodicity of phase plates for TEM. Ultramicroscopy. 2011; 111(8):1305-15. DOI: 10.1016/j.ultramic.2011.04.004. View

3.
Kumar P, Bernardi M, Grossman J . The impact of functionalization on the stability, work function, and photoluminescence of reduced graphene oxide. ACS Nano. 2013; 7(2):1638-45. DOI: 10.1021/nn305507p. View

4.
Nagayama K, Danev R . Phase contrast electron microscopy: development of thin-film phase plates and biological applications. Philos Trans R Soc Lond B Biol Sci. 2008; 363(1500):2153-62. PMC: 2453530. DOI: 10.1098/rstb.2008.2268. View

5.
Fukuda Y, Fukazawa Y, Danev R, Shigemoto R, Nagayama K . Tuning of the Zernike phase-plate for visualization of detailed ultrastructure in complex biological specimens. J Struct Biol. 2009; 168(3):476-84. DOI: 10.1016/j.jsb.2009.08.011. View