» Articles » PMID: 25323907

Real Stereopsis Test Using a Three-dimensional Display with Tridef Software

Overview
Journal Yonsei Med J
Specialty General Medicine
Date 2014 Oct 18
PMID 25323907
Citations 5
Authors
Affiliations
Soon will be listed here.
Abstract

Purpose: To investigate horizontal image disparity in three-dimensional (3-D) perception using 3-D animations in normal control patients and patients with intermittent exotropia, anisometropic amblyopia, and partially accommodative esotropia.

Materials And Methods: A total of 133 subjects were included. Stereopsis was measured using the Titmus Stereo test (Stereo Optical Inc., Chicago, IL, USA) and a 3-D stereopsis test with a 15 inch 3-D display laptop, adjusting 3-D parameters of 0 mm horizontal disparity to 15 mm horizontal disparity.

Results: When compared with normal controls, the average threshold of the 3-D stereopsis test was significantly reduced for esotropia patients (p<0.001) and for anisometric amblyopia patients (p<0.001), compared to normal controls. No significant difference was observed between normal controls and intermittent exotropia patients (p=0.082). The 3-D stereopsis test was correlated with the Titmus Stereo test (Spearman's rho=0.690, p<0.001). Mean difference in stereoacuity was 1.323 log seconds of arc (95% limits of agreement: 0.486 to 2.112), and 125 (92.5%) patients were within the limits of agreement.

Conclusion: This study demonstrated that a 3-D stereopsis test with animation is highly correlated with the Titmus Stereo test; nevertheless, 3-D stereopsis with animations generates more image disparities than the conventional Titmus Stereo test. The 3-D stereopsis test is highly predictive for estimating real stereopsis in a 3-D movie theater.

Citing Articles

Screening for Stereopsis Using an Eye-Tracking Glasses-Free Display in Adults: A Pilot Study.

Liu F, Zhao J, Han T, Shen Y, Li M, Liu J Front Med (Lausanne). 2022; 8:814908.

PMID: 35118100 PMC: 8804875. DOI: 10.3389/fmed.2021.814908.


Effect of chromatic contrast on stereoacuity measurement with computer-aided three-dimensional technology.

Zhao L, Wu H Ann Transl Med. 2019; 7(9):192.

PMID: 31205910 PMC: 6545307. DOI: 10.21037/atm.2019.03.57.


Evaluating stereoacuity with 3D shutter glasses technology.

Wu H, Jin H, Sun Y, Wang Y, Ge M, Chen Y BMC Ophthalmol. 2016; 16(1):45.

PMID: 27112418 PMC: 4845396. DOI: 10.1186/s12886-016-0223-3.


Stereoscopic perception of 3-D images by patients after surgery for esotropia.

Endo T, Fujikado T, Shimojyo H, Kanda H, Morimoto T, Nishida K Jpn J Ophthalmol. 2015; 60(1):7-13.

PMID: 26564209 DOI: 10.1007/s10384-015-0419-8.


Distance stereotesting using vision test charts for intermittent exotropia.

Nishikawa N, Ishiko S, Yamaga I, Sato M, Yoshida A Clin Ophthalmol. 2015; 9:1557-62.

PMID: 26346264 PMC: 4556247. DOI: 10.2147/OPTH.S89727.

References
1.
Birch E, Wang J . Stereoacuity outcomes after treatment of infantile and accommodative esotropia. Optom Vis Sci. 2009; 86(6):647-52. PMC: 2769257. DOI: 10.1097/OPX.0b013e3181a6168d. View

2.
Birch E . Marshall Parks lecture. Binocular sensory outcomes in accommodative ET. J AAPOS. 2004; 7(6):369-73. DOI: 10.1016/j.jaapos.2003.08.003. View

3.
Westheimer G . Clinical evaluation of stereopsis. Vision Res. 2012; 90:38-42. DOI: 10.1016/j.visres.2012.10.005. View

4.
Adams W, Leske D, Hatt S, Mohney B, Birch E, Weakley Jr D . Improvement in distance stereoacuity following surgery for intermittent exotropia. J AAPOS. 2007; 12(2):141-4. PMC: 2675644. DOI: 10.1016/j.jaapos.2007.09.015. View

5.
Fawcett S, Birch E . Interobserver test-retest reliability of the Randot preschool stereoacuity test. J AAPOS. 2000; 4(6):354-8. DOI: 10.1067/mpa.2000.110340. View