Newer Methods of Cardiac Output Monitoring

Overview
Journal World J Cardiol
Date 2014 Oct 3
PMID 25276302
Citations 38
Authors
Affiliations
Soon will be listed here.
Abstract

Cardiac output (CO) is the volume of blood ejected by each ventricle per minute and is the product of stroke volume and heart rate. CO can thus be manipulated by alteration in heart rate or rhythm, preload, contractility and afterload. Moreover it gives important information about tissue perfusion and oxygen delivery. CO can be measured by various methods and thermodilution method using pulmonary artery catheter (PAC) is till date considered as gold standard method. Complications associated with PAC led to development of newer methods which are minimally or non-invasive. Newer methods fulfil other properties like continuous and reproducible reading, cost effective, reliable during various physiological states and have fast response time. These methods are validated against the gold standard with good level agreement. In this review we have discussed various newer methods of CO monitoring and their effectiveness in clinical use.

Citing Articles

Performance evaluation of non-invasive cardiac output monitoring device (HemoVista) based on multi-channel thoracic impedance plethysmography technology.

Park J, Choi B Acute Crit Care. 2024; 39(4):565-572.

PMID: 39558594 PMC: 11617851. DOI: 10.4266/acc.2024.00731.


Pulmonary Embolism in Critically Ill Patients-Prevention, Diagnosis, and Management.

Vrettou C, Dima E, Sigala I Diagnostics (Basel). 2024; 14(19).

PMID: 39410612 PMC: 11475110. DOI: 10.3390/diagnostics14192208.


Realistic Aspects of Cardiac Ultrasound in Rats: Practical Tips for Improved Examination.

Silva J, Azevedo T, Ginja M, Oliveira P, Duarte J, Faustino-Rocha A J Imaging. 2024; 10(9).

PMID: 39330439 PMC: 11433567. DOI: 10.3390/jimaging10090219.


LDCNN: A new arrhythmia detection technique with ECG signals using a linear deep convolutional neural network.

Bayani A, Kargar M Physiol Rep. 2024; 12(17):e16182.

PMID: 39218586 PMC: 11366442. DOI: 10.14814/phy2.16182.


Technical and analytical approach to biventricular pressure-volume loops in swine including a completely endovascular, percutaneous closed-chest large animal model.

Stonko D, Rousseau M, Price C, Benike A, Treffalls R, Brunton N JVS Vasc Sci. 2024; 5:100190.

PMID: 38486870 PMC: 10938295. DOI: 10.1016/j.jvssci.2024.100190.


References
1.
Bland J, Altman D . Statistical methods for assessing agreement between two methods of clinical measurement. Lancet. 1986; 1(8476):307-10. View

2.
Halvorsen P, Sokolov A, Cvancarova M, Hol P, Lundblad R, Tonnessen T . Continuous cardiac output during off-pump coronary artery bypass surgery: pulse-contour analyses vs pulmonary artery thermodilution. Br J Anaesth. 2007; 99(4):484-92. DOI: 10.1093/bja/aem199. View

3.
De Backer D, Marx G, Tan A, Junker C, Van Nuffelen M, Huter L . Arterial pressure-based cardiac output monitoring: a multicenter validation of the third-generation software in septic patients. Intensive Care Med. 2010; 37(2):233-40. PMC: 3028067. DOI: 10.1007/s00134-010-2098-8. View

4.
Sakka S, Kozieras J, Thuemer O, van Hout N . Measurement of cardiac output: a comparison between transpulmonary thermodilution and uncalibrated pulse contour analysis. Br J Anaesth. 2007; 99(3):337-42. DOI: 10.1093/bja/aem177. View

5.
Gore J, Goldberg R, Spodick D, Alpert J, Dalen J . A community-wide assessment of the use of pulmonary artery catheters in patients with acute myocardial infarction. Chest. 1987; 92(4):721-7. DOI: 10.1378/chest.92.4.721. View