» Articles » PMID: 25163822

The Effect of Local Anatomy on the Electric Field Induced by TMS: Evaluation at 14 Different Target Sites

Overview
Publisher Springer
Date 2014 Aug 29
PMID 25163822
Citations 16
Authors
Affiliations
Soon will be listed here.
Abstract

Many human cortical regions are targeted with transcranial magnetic stimulation (TMS). The stimulus intensity used for a certain region is generally based on the motor threshold stimulation intensity determined over the motor cortex (M1). However, it is well known that differences exist in coil-target distance and target site anatomy between cortical regions. These differences may well make the stimulation intensity derived from M1 sub-optimal for other regions. Our goal was to determine in what way the induced electric fields differ between cortical target regions. We used finite element method modeling to calculate the induced electric field for multiple target sites in a realistic head model. The effects on the electric field due to coil-target distance and target site anatomy have been quantified. The results show that a correction based on the distance alone does not correctly adjust the induced electric field for regions other than M1. In addition, a correction based solely on the TMS-induced electric field (primary field) does not suffice. A precise adjustment should include coil-target distance, the secondary field caused by charge accumulation at conductivity discontinuities and the direction of the field relative to the local cerebrospinal fluid-grey matter boundary.

Citing Articles

Evoked EEG Responses to TMS Targeting Regions Outside the Primary Motor Cortex and Their Test-Retest Reliability.

Song Y, Gordon P, Metsomaa J, Rostami M, Belardinelli P, Ziemann U Brain Topogr. 2023; 37(1):19-36.

PMID: 37996562 PMC: 10771591. DOI: 10.1007/s10548-023-01018-y.


Outcome measures for electric field modeling in tES and TMS: A systematic review and large-scale modeling study.

Hoornweder S, Nuyts M, Frieske J, Verstraelen S, Meesen R, Caulfield K Neuroimage. 2023; 281:120379.

PMID: 37716590 PMC: 11008458. DOI: 10.1016/j.neuroimage.2023.120379.


Mapping Brain Motor Functions Using Transcranial Magnetic Stimulation with a Volume Conductor Model and Electrophysiological Experiments.

Hikita K, Gomez-Tames J, Hirata A Brain Sci. 2023; 13(1).

PMID: 36672097 PMC: 9856731. DOI: 10.3390/brainsci13010116.


Transcranial magnetic stimulation treatment in Alzheimer's disease: a meta-analysis of its efficacy as a function of protocol characteristics and degree of personalization.

Menardi A, Dotti L, Ambrosini E, Vallesi A J Neurol. 2022; 269(10):5283-5301.

PMID: 35781536 PMC: 9468063. DOI: 10.1007/s00415-022-11236-2.


Transcranial magnetic stimulation of the brain: What is stimulated? - A consensus and critical position paper.

Siebner H, Funke K, Aberra A, Antal A, Bestmann S, Chen R Clin Neurophysiol. 2022; 140:59-97.

PMID: 35738037 PMC: 9753778. DOI: 10.1016/j.clinph.2022.04.022.


References
1.
Trillenberg P, Bremer S, Oung S, Erdmann C, Schweikard A, Richter L . Variation of stimulation intensity in transcranial magnetic stimulation with depth. J Neurosci Methods. 2012; 211(2):185-90. DOI: 10.1016/j.jneumeth.2012.09.007. View

2.
Thielscher A, Opitz A, Windhoff M . Impact of the gyral geometry on the electric field induced by transcranial magnetic stimulation. Neuroimage. 2010; 54(1):234-43. DOI: 10.1016/j.neuroimage.2010.07.061. View

3.
Salinas F, Lancaster J, Fox P . Detailed 3D models of the induced electric field of transcranial magnetic stimulation coils. Phys Med Biol. 2007; 52(10):2879-92. DOI: 10.1088/0031-9155/52/10/016. View

4.
Arai N, Lu M, Ugawa Y, Ziemann U . Effective connectivity between human supplementary motor area and primary motor cortex: a paired-coil TMS study. Exp Brain Res. 2012; 220(1):79-87. DOI: 10.1007/s00221-012-3117-5. View

5.
Mills K, Boniface S, Schubert M . Magnetic brain stimulation with a double coil: the importance of coil orientation. Electroencephalogr Clin Neurophysiol. 1992; 85(1):17-21. DOI: 10.1016/0168-5597(92)90096-t. View