» Articles » PMID: 25154770

Establishing Ion Ratio Thresholds Based on Absolute Peak Area for Absolute Protein Quantification Using Protein Cleavage Isotope Dilution Mass Spectrometry

Overview
Journal Analyst
Specialty Chemistry
Date 2014 Aug 27
PMID 25154770
Citations 3
Authors
Affiliations
Soon will be listed here.
Abstract

Quantitative mass spectrometry has become central to the field of proteomics and metabolomics. Selected reaction monitoring is a widely used method for the absolute quantification of proteins and metabolites. This method renders high specificity using several product ions measured simultaneously. With growing interest in quantification of molecular species in complex biological samples, confident identification and quantitation has been of particular concern. A method to confirm purity or contamination of product ion spectra has become necessary for achieving accurate and precise quantification. Ion abundance ratio assessments were introduced to alleviate some of these issues. Ion abundance ratios are based on the consistent relative abundance (RA) of specific product ions with respect to the total abundance of all product ions. To date, no standardized method of implementing ion abundance ratios has been established. Thresholds by which product ion contamination is confirmed vary widely and are often arbitrary. This study sought to establish criteria by which the relative abundance of product ions can be evaluated in an absolute quantification experiment. These findings suggest that evaluation of the absolute ion abundance for any given transition is necessary in order to effectively implement RA thresholds. Overall, the variation of the RA value was observed to be relatively constant beyond an absolute threshold ion abundance. Finally, these RA values were observed to fluctuate significantly over a 3 year period, suggesting that these values should be assessed as close as possible to the time at which data is collected for quantification.

Citing Articles

Multistage Detection of Tetrodotoxin Traces in Collected in El Salvador.

Fuentes-Monteverde J, Nunez M, Amaya-Monterosa O, Martinez M, Rodriguez J, Jimenez C Toxins (Basel). 2023; 15(7).

PMID: 37505678 PMC: 10467132. DOI: 10.3390/toxins15070409.


Liquid Chromatography-Tandem Mass Spectrometry Analysis of Acetaminophen Covalent Binding to Glutathione -Transferases.

Geib T, Lento C, Wilson D, Sleno L Front Chem. 2019; 7:558.

PMID: 31457004 PMC: 6700392. DOI: 10.3389/fchem.2019.00558.


N-linked glycosite profiling and use of Skyline as a platform for characterization and relative quantification of glycans in differentiating xylem of Populus trichocarpa.

Loziuk P, Hecht E, Muddiman D Anal Bioanal Chem. 2016; 409(2):487-497.

PMID: 27491298 PMC: 5209793. DOI: 10.1007/s00216-016-9776-5.

References
1.
de Zeeuw R . Substance identification: the weak link in analytical toxicology. J Chromatogr B Analyt Technol Biomed Life Sci. 2004; 811(1):3-12. DOI: 10.1016/j.jchromb.2004.07.043. View

2.
Sauvage F, Gaulier J, Lachatre G, Marquet P . Pitfalls and prevention strategies for liquid chromatography-tandem mass spectrometry in the selected reaction-monitoring mode for drug analysis. Clin Chem. 2008; 54(9):1519-27. DOI: 10.1373/clinchem.2008.105478. View

3.
Shuford C, Li Q, Sun Y, Chen H, Wang J, Shi R . Comprehensive quantification of monolignol-pathway enzymes in Populus trichocarpa by protein cleavage isotope dilution mass spectrometry. J Proteome Res. 2012; 11(6):3390-404. DOI: 10.1021/pr300205a. View

4.
Scopes R . Measurement of protein by spectrophotometry at 205 nm. Anal Biochem. 1974; 59(1):277-82. DOI: 10.1016/0003-2697(74)90034-7. View

5.
MacLean B, Tomazela D, Abbatiello S, Zhang S, Whiteaker J, Paulovich A . Effect of collision energy optimization on the measurement of peptides by selected reaction monitoring (SRM) mass spectrometry. Anal Chem. 2010; 82(24):10116-24. PMC: 3005404. DOI: 10.1021/ac102179j. View