» Articles » PMID: 18465883

Towards Absolute Quantification of Therapeutic Monoclonal Antibody in Serum by LC-MS/MS Using Isotope-labeled Antibody Standard and Protein Cleavage Isotope Dilution Mass Spectrometry

Overview
Journal Anal Chem
Specialty Chemistry
Date 2008 May 10
PMID 18465883
Citations 34
Authors
Affiliations
Soon will be listed here.
Abstract

Although LC-MS methods are increasingly used for the absolute quantification of proteins, the lack of appropriate internal standard (IS) hinders the development of rapid and standardized analytical methods for both in vitro and in vivo studies. Here, we have developed a novel method for the absolute quantification of a therapeutic protein, which is monoclonal antibody (mAb). The method combines liquid chromatography tandem mass spectrometry (LC-MS/MS) and protein cleavage isotope dilution mass spectrometry with the isotope-labeled mAb as IS. The latter was identical to the analyzed mAb with the exception that each threonine contains four (13)C atoms and one (15)N atom. Serum samples were spiked with IS prior to the overnight trypsin digestion and subsequent sample cleanup. Sample extracts were analyzed on a C18 ACE column (150 mm x 4.6 mm) using an LC gradient time of 11 min. Endogenous mAb concentrations were determined by calculating the peak height ratio of its signature peptide to the corresponding isotope-labeled peptide. The linear dynamic range was established between 5.00 and 1000 microg/mL mAb with accuracy and precision within +/-15% at all concentrations and below +/-20% at the LLOQ (lower limit of quantification). The overall method recovery in terms of mAb was 14%. The losses due to sample preparation (digestion and purification) were 72% from which about 32% was due to the first step of the method, the sample digestion. This huge loss during sample preparation strongly emphasizes the necessity to employ an IS right from the beginning. Our method was successfully applied to the mAb quantification in marmoset serum study samples, and the precision obtained on duplicate samples was, in most cases, below 20%. The comparison with enzyme-linked immunosorbent assay (ELISA) showed higher exposure in terms of AUC and Cmax with the LC-MS/MS method. Possible reasons for this discrepancy are discussed in this study. The results of this study indicate that our LC-MS/MS method is a simple, rapid, and precise approach for the therapeutic mAb quantification to support preclinical and clinical studies.

Citing Articles

Challenges and Insights in Absolute Quantification of Recombinant Therapeutic Antibodies by Mass Spectrometry: An Introductory Review.

Doring S, Weller M, Reinders Y, Konthur Z, Jaeger C Antibodies (Basel). 2025; 14(1.

PMID: 39846611 PMC: 11755444. DOI: 10.3390/antib14010003.


Generic Enrichment Method for Liquid Chromatography-Multiple Reaction Monitoring-Mass Spectrometry Assay for Quantitative Measurement of Biological Therapeutics in Serum.

Zhang S, Xiao H, Li N Pharm Res. 2024; 41(9):1881-1892.

PMID: 39174718 DOI: 10.1007/s11095-024-03759-2.


Understanding the pharmacokinetic journey of Fc-fusion protein, rhIL-7-hyFc using complementary approach of two analytical methods, accelerator mass spectrometry and ELISA.

Kim A, Oh M, Lee G, Song S, Byun M, Choi D Antib Ther. 2024; 7(2):105-113.

PMID: 38566969 PMC: 10983079. DOI: 10.1093/abt/tbae004.


Immunocapture LC-MS methods for pharmacokinetics of large molecule drugs.

Werth E, Roos D, Philip E Bioanalysis. 2024; 16(7):165-177.

PMID: 38348660 PMC: 11845110. DOI: 10.4155/bio-2023-0261.


Enhanced Pharmacokinetic Bioanalysis of Antibody-drug Conjugates using Hybrid Immunoaffinity Capture and Microflow LC-MS/MS.

Suh M, Powers J, Daniels C, Wu Y AAPS J. 2023; 25(4):68.

PMID: 37386323 DOI: 10.1208/s12248-023-00835-0.