» Articles » PMID: 25142803

Surgical Treatment for Pyogenic Vertebral Osteomyelitis Using Iodine-supported Spinal Instruments: Initial Case Series of 14 Patients

Overview
Publisher Springer
Date 2014 Aug 22
PMID 25142803
Citations 3
Authors
Affiliations
Soon will be listed here.
Abstract

Reports have detailed the increasing use of spinal instrumentation in the treatment of pyogenic vertebral osteomyelitis, with the aims of achieving a lower pseudoarthrosis rate and restoring spinal alignment. However, controversy remains over the use of instrumentation in the presence of active infection because of concerns about increased bacterial adherence and biofilm formation on the metallic implant surface. Fourteen consecutive patients were followed who were diagnosed as having pyogenic vertebral osteomyelitis and underwent surgery with spinal instrumentation with iodine-containing surfaces that could be directly supported to existing titanium implants. Bone-cage interfaces and implant-related complications after surgery were evaluated. The white blood cell (WBC) count and C-reactive protein (CRP) level were analyzed during the follow-up period. To confirm the influence of iodine release from the implant, thyroid-stimulating hormone (TSH), free triiodothyronine (FT3), and free thyroxine (FT4) were also examined. The infection subsided in all 14 patients. Both WBC counts and CRP levels returned to normal ranges by the final follow-up. One patient showed a lucent area around the screw and two patients showed lucencies inside the cage. However, no cage dislocations, cage migrations, or screw pull-outs were noted, and all patients' FT3, FT4, and TSH levels were within normal ranges during the follow-up period. We demonstrated the efficacy of iodine-supported titanium implants in the management of pyogenic vertebral osteomyelitis. No cytotoxicity or adverse effects were noted in this series.

Citing Articles

First Clinical Evidence About the Use of a New Silver-Coated Titanium Alloy Instrumentation to Counteract Surgical Site Infection at the Spine Level.

Leggi L, Terzi S, Sartori M, Salamanna F, Boriani L, Asunis E J Funct Biomater. 2025; 16(1).

PMID: 39852586 PMC: 11766446. DOI: 10.3390/jfb16010030.


Development of Silver-Containing Hydroxyapatite-Coated Antimicrobial Implants for Orthopaedic and Spinal Surgery.

Morimoto T, Hirata H, Eto S, Hashimoto A, Kii S, Kobayashi T Medicina (Kaunas). 2022; 58(4).

PMID: 35454358 PMC: 9029955. DOI: 10.3390/medicina58040519.


Mesh cage for treatment of hematogenous spondylitis and spondylodiskitis. How safe and successful is its use in acute and chronic complicated cases? A systematic review of literature over a decade.

Korovessis P, Vardakastanis K, Fennema P, Syrimbeis V Eur J Orthop Surg Traumatol. 2016; 26(7):753-61.

PMID: 27324195 DOI: 10.1007/s00590-016-1803-x.


Iodine-Supported Hip Implants: Short Term Clinical Results.

Kabata T, Maeda T, Kajino Y, Hasegawa K, Inoue D, Yamamoto T Biomed Res Int. 2015; 2015:368124.

PMID: 26583103 PMC: 4637032. DOI: 10.1155/2015/368124.

References
1.
Grammatico L, Baron S, Rusch E, Lepage B, Surer N, Desenclos J . Epidemiology of vertebral osteomyelitis (VO) in France: analysis of hospital-discharge data 2002-2003. Epidemiol Infect. 2007; 136(5):653-60. PMC: 2870846. DOI: 10.1017/S0950268807008850. View

2.
Cheung W, Luk K . Pyogenic spondylitis. Int Orthop. 2011; 36(2):397-404. PMC: 3282872. DOI: 10.1007/s00264-011-1384-6. View

3.
Chen W, Jiang L, Dai L . Influence of bacteria on spinal implant-centered infection: an in vitro and in vivo experimental comparison between Staphylococcus aureus and mycobacterium tuberculosis. Spine (Phila Pa 1976). 2010; 36(2):103-8. DOI: 10.1097/BRS.0b013e3181cb46ba. View

4.
Hardes J, von Eiff C, Streitbuerger A, Balke M, Budny T, Henrichs M . Reduction of periprosthetic infection with silver-coated megaprostheses in patients with bone sarcoma. J Surg Oncol. 2010; 101(5):389-95. DOI: 10.1002/jso.21498. View

5.
Shirai T, Shimizu T, Ohtani K, Zen Y, Takaya M, Tsuchiya H . Antibacterial iodine-supported titanium implants. Acta Biomater. 2010; 7(4):1928-33. DOI: 10.1016/j.actbio.2010.11.036. View