» Articles » PMID: 10984710

Prevention of Pin Track Infection in External Fixation with Silver Coated Pins: Clinical and Microbiological Results

Overview
Date 2000 Sep 14
PMID 10984710
Citations 51
Authors
Affiliations
Soon will be listed here.
Abstract

Pin tract infection is a frequent complication of external fixation; according to literature its frequency ranges from 2-30%. The recent introduction of silver coating of polymeric materials was found to decrease bacterial adhesion; its clinical use with Foley catheters and central venous catheters led to significant results. To verify the ability of the same silver coating to decrease the bacterial colonization on external fixation screws, a prospective randomized study was carried out on 24 male patients; a total of 106 screws were implanted in the lower limb to fix femoral or tibial diaphyseal fractures: 50 were coated with silver and 56 were commercially available stainless steel screws. Although the coated screws resulted in a lower rate of positive cultures (30.0%) than the uncoated screws (42.9%), this difference was not statistically significant (p = 0.243). The clinical behavior of the coated screws did not differ from that of the uncoated ones. Furthermore, the implant of silver-coated screws resulted in a significant increase in the silver serum level. These results led us to consider it ethically unacceptable to continue this investigation.

Citing Articles

Enhancing Antibacterial Properties of Titanium Implants through Covalent Conjugation of Self-Assembling Fmoc-Phe-Phe Dipeptide on Titania Nanotubes.

Singh R, Popat K ACS Appl Mater Interfaces. 2024; 16(45):61714-61724.

PMID: 39478289 PMC: 11565481. DOI: 10.1021/acsami.4c13885.


What to Know about Antimicrobial Coatings in Arthroplasty: A Narrative Review.

Onorato F, Masoni V, Gagliardi L, Comba L, Rivera F Medicina (Kaunas). 2024; 60(4).

PMID: 38674220 PMC: 11052078. DOI: 10.3390/medicina60040574.


Potential side effects of antibacterial coatings in orthopaedic implants: A systematic review of clinical studies.

Li H, Wang D, Zhang W, Xu G, Xu C, Liu W Front Bioeng Biotechnol. 2023; 11:1111386.

PMID: 36845182 PMC: 9947536. DOI: 10.3389/fbioe.2023.1111386.


Hydroxyapatite-coated compared with stainless steel external fixation pins did not show impact in the rate of pin track infection: a multicenter prospective study.

Stoffel C, de Lima E, Salles M Int Orthop. 2023; 47(5):1163-1169.

PMID: 36773051 PMC: 9918829. DOI: 10.1007/s00264-023-05717-w.


Fungal-derived selenium nanoparticles and their potential applications in electroless silver coatings for preventing pin-tract infections.

Liang X, Zhang S, Gadd G, McGrath J, Rooney D, Zhao Q Regen Biomater. 2022; 9(1):rbac013.

PMID: 35449828 PMC: 9017370. DOI: 10.1093/rb/rbac013.