» Articles » PMID: 25060830

EXOGEN Ultrasound Bone Healing System for Long Bone Fractures with Non-union or Delayed Healing: a NICE Medical Technology Guidance

Overview
Specialty Public Health
Date 2014 Jul 26
PMID 25060830
Citations 26
Authors
Affiliations
Soon will be listed here.
Abstract

A routine part of the process for developing National Institute for Health and Care Excellence (NICE) medical technologies guidance is a submission of clinical and economic evidence by the technology manufacturer. The Birmingham and Brunel Consortium External Assessment Centre (EAC; a consortium of the University of Birmingham and Brunel University) independently appraised the submission on the EXOGEN bone healing system for long bone fractures with non-union or delayed healing. This article is an overview of the original evidence submitted, the EAC's findings, and the final NICE guidance issued.

Citing Articles

The Mechanotransduction Signaling Pathways in the Regulation of Osteogenesis.

Liu Z, Wang Q, Zhang J, Qi S, Duan Y, Li C Int J Mol Sci. 2023; 24(18).

PMID: 37762629 PMC: 10532275. DOI: 10.3390/ijms241814326.


Multicenter consensus statements on the use of low-intensity pulsed ultrasound (LIPUS) in Hand Surgery.

Struckmann V, Stolle A, Bocker A, Hagl S, Kneser U, Harhaus L Arch Orthop Trauma Surg. 2023; 143(11):6965-6972.

PMID: 37578657 DOI: 10.1007/s00402-023-05023-5.


Low-Intensity Pulsed Ultrasound Treatment for Non-unions of Long Bone Fractures in a Scottish District General Hospital.

Haller P, Nunag P, Papadopoulos A Cureus. 2023; 15(1):e34159.

PMID: 36843729 PMC: 9949742. DOI: 10.7759/cureus.34159.


Low-Intensity Pulsed Ultrasound Therapy in Patients With Post-traumatic Delayed Union and Non-union.

Pretorius J, Barry M, Fadul A, Murphy C Cureus. 2023; 14(12):e32267.

PMID: 36620791 PMC: 9815886. DOI: 10.7759/cureus.32267.


A Retrospective Study: Is Low-Intensity Pulsed Ultrasound (LIPUS) an Effective Alternate Treatment Option for Non-union?.

Pretorius J, Mohamed Y, Mustafa A, Nemat N, Ellanti P, Hammad Y Cureus. 2022; 14(9):e29230.

PMID: 36277550 PMC: 9578507. DOI: 10.7759/cureus.29230.


References
1.
Withers K, Carolan-Rees G, Dale M . Pipeline™ embolization device for the treatment of complex intracranial aneurysms: a NICE Medical Technology Guidance. Appl Health Econ Health Policy. 2013; 11(1):5-13. PMC: 3563954. DOI: 10.1007/s40258-012-0005-x. View

2.
Ring D, Jupiter J, Sanders R, Quintero J, Santoro V, Ganz R . Complex nonunion of fractures of the femoral shaft treated by wave-plate osteosynthesis. J Bone Joint Surg Br. 1997; 79(2):289-94. DOI: 10.1302/0301-620x.79b2.6886. View

3.
Rutten S, Nolte P, Korstjens C, van Duin M, Klein-Nulend J . Low-intensity pulsed ultrasound increases bone volume, osteoid thickness and mineral apposition rate in the area of fracture healing in patients with a delayed union of the osteotomized fibula. Bone. 2008; 43(2):348-354. DOI: 10.1016/j.bone.2008.04.010. View

4.
Jingushi S, Mizuno K, Matsushita T, Itoman M . Low-intensity pulsed ultrasound treatment for postoperative delayed union or nonunion of long bone fractures. J Orthop Sci. 2007; 12(1):35-41. DOI: 10.1007/s00776-006-1080-3. View

5.
Donaldson L, Reckless I, Scholes S, Mindell J, Shelton N . The epidemiology of fractures in England. J Epidemiol Community Health. 2008; 62(2):174-80. DOI: 10.1136/jech.2006.056622. View