Background And Purpose: Flow diverters are designed to occlude aneurysms while preserving flow to jailed arterial branches. We postulated that treatment success depended on the size of the aneurysm ostium or defect in the parent artery.

Materials And Methods: Flow diverter expansion and deformation were studied in silicone tubes with wall apertures of various sizes. Large and giant canine sidewall aneurysms, featuring a branch located immediately opposite the aneurysm, and a smaller 6- to 8-mm (group A, n = 6) or a larger 10- to 16-mm (group B, n = 6) ostium were created to study the effects of ostium size on aneurysm or branch occlusion by flow diverters. Angiographic results after deployment and at 3 months were scored by using an ordinal scale. The amount of neointima formation on the segment of the device overlying the aneurysm or the branch ostia was determined by specimen photography.

Results: The fusiform deformation of flow diverters was maximal with larger defects in silicone tubes. At 3 months, group B aneurysms showed worse angiographic results than group A aneurysms, with larger residual aneurysm volumes (P = .002). Neointimal coverage of the aneurysm ostia was more complete in group A compared with group B (P = .002).

Conclusions: The effects of flow diversion may vary with the size of the aneurysm ostium.

Citing Articles

Safety and efficacy of pipeline embolization device treatments for intradural internal carotid artery aneurysms in a single center in a Japanese population.

Kitamura T, Fujii T, Yatomi K, Teranishi K, Mitome-Mishima Y, Oishi H Surg Neurol Int. 2023; 14:92.

PMID: 37025526 PMC: 10070317. DOI: 10.25259/SNI_1165_2022.


Efficacy and safety of flow diverters in posterior circulation aneurysms and comparison with their efficacy in anterior circulation aneurysms: A systematic review and meta-analysis.

Abdel-Tawab M, Abdeltawab A, Abdelmonem M, Moubark M, Taha M, Morsy A Interv Neuroradiol. 2021; 27(5):609-621.

PMID: 33752478 PMC: 8493351. DOI: 10.1177/15910199211003017.


On Flow Diversion: The Changing Landscape of Intracerebral Aneurysm Management.

Dmytriw A, Phan K, Moore J, Pereira V, Krings T, Thomas A AJNR Am J Neuroradiol. 2019; 40(4):591-600.

PMID: 30894358 PMC: 7048527. DOI: 10.3174/ajnr.A6006.


Ostium Ratio and Neck Ratio Could Predict the Outcome of Sidewall Intracranial Aneurysms Treated with Flow Diverters.

Paliwal N, Tutino V, Shallwani H, Beecher J, Damiano R, Shakir H AJNR Am J Neuroradiol. 2019; 40(2):288-294.

PMID: 30679216 PMC: 6375759. DOI: 10.3174/ajnr.A5953.


Outcome prediction of intracranial aneurysm treatment by flow diverters using machine learning.

Paliwal N, Jaiswal P, Tutino V, Shallwani H, Davies J, Siddiqui A Neurosurg Focus. 2018; 45(5):E7.

PMID: 30453461 PMC: 6421840. DOI: 10.3171/2018.8.FOCUS18332.


References
1.
Bing F, Darsaut T, Salazkin I, Makoyeva A, Gevry G, Raymond J . Stents and flow diverters in the treatment of aneurysms: device deformation in vivo may alter porosity and impact efficacy. Neuroradiology. 2012; 55(1):85-92. DOI: 10.1007/s00234-012-1082-0. View

2.
Darsaut T, Bing F, Salazkin I, Gevry G, Raymond J . Flow diverters failing to occlude experimental bifurcation or curved sidewall aneurysms: an in vivo study in canines. J Neurosurg. 2012; 117(1):37-44. DOI: 10.3171/2012.4.JNS111916. View

3.
Piano M, Valvassori L, Quilici L, Pero G, Boccardi E . Midterm and long-term follow-up of cerebral aneurysms treated with flow diverter devices: a single-center experience. J Neurosurg. 2012; 118(2):408-16. DOI: 10.3171/2012.10.JNS112222. View

4.
Szikora I, Berentei Z, Kulcsar Z, Marosfoi M, Vajda Z, Lee W . Treatment of intracranial aneurysms by functional reconstruction of the parent artery: the Budapest experience with the pipeline embolization device. AJNR Am J Neuroradiol. 2010; 31(6):1139-47. PMC: 7963954. DOI: 10.3174/ajnr.A2023. View

5.
Becske T, Kallmes D, Saatci I, McDougall C, Szikora I, Lanzino G . Pipeline for uncoilable or failed aneurysms: results from a multicenter clinical trial. Radiology. 2013; 267(3):858-68. DOI: 10.1148/radiol.13120099. View