Background: Mechanically aligned total knee arthroplasty can create a tight collateral ligament in 0° of extension, instability in a compartment between 0° of extension and 90° of flexion that is uncorrectable by collateral ligament release, and changes in limb and knee alignment from normal. The goal of the present study was to calculate the frequency and range of these undesirable consequences.

Methods: Four methods of mechanically aligned total knee arthroplasty were simulated on fifty normal three-dimensional bone models of the lower extremity from white subjects. Each method resected the distal aspect of the femur and proximal aspect of the tibia perpendicular to their respective mechanical axes. Setting the posterior joint line perpendicular to the anteroposterior axis of the trochlear groove (Method 1), parallel to the transepicondylar axis (Method 2), externally rotated 3° with respect to the posterior condylar axis (Method 3), and parallel to the tibial resection in 90° of flexion with the use of gap-balancing (Method 4) aligned internal-external rotation of the femoral component.

Results: The proportion of total knee arthroplasties requiring a ≥2-mm release of a tight collateral ligament was 34% for the medial collateral ligament and 30% for the lateral collateral ligament. The proportion of total knee arthroplasties with ≥2 mm of instability between 0° of extension and 90° of flexion was 56% in the medial compartment and 6% in the lateral compartment for Method 1, 74% and 6% for Method 2, and 42% and 0% for Method 3. Method 4 did not cause ligamentous instability. The proportion of arthroplasties with a ≥2° change from normal was 58% for limb alignment and 58% for knee alignment.

Conclusions: Surgeons should be aware that, when using the four methods of mechanically aligning a total knee arthroplasty, they will frequently have to manage a wide range of collateral ligament imbalances that are complex, cumulative, and uncorrectable by collateral ligament release, and a wide range of changes in limb and knee alignment from normal. Patients who perceive these changes in stability, limb alignment, and knee alignment may be dissatisfied and require counseling.

Citing Articles

Functional Alignment Achieved a More Balanced Knee After Robotic Arm-Assisted Total Knee Arthroplasty than Modified Kinematic Alignment.

Yang H, Seon J, Yim J, Lee D, Song E J Clin Med. 2025; 14(3).

PMID: 39941491 PMC: 11818173. DOI: 10.3390/jcm14030820.


The location of the centre of the proximal quadriceps tendon in kinematically aligned total knee arthroplasty is not associated with poor outcome scores or symptomatic patellar instability.

Razick D, Akhtar M, Howell S, Nedopil A, Hull M J Exp Orthop. 2024; 11(4):e70075.

PMID: 39540019 PMC: 11558114. DOI: 10.1002/jeo2.70075.


A Novel Technique for Restricted Kinematic Alignment Total Knee Arthroplasty Without Computer-Assisted Devices.

Sakakibara Y, Yasutani Y, Oyama A, Teramoto A Cureus. 2024; 16(8):e67233.

PMID: 39301339 PMC: 11412279. DOI: 10.7759/cureus.67233.


Kinematic Alignment Achieves a More Balanced Total Knee Arthroplasty Than Mechanical Alignment among CPAK Type I Patients: A Simulation Study.

Arai N, Toyooka S, Masuda H, Kawano H, Nakagawa T J Clin Med. 2024; 13(12).

PMID: 38930125 PMC: 11204712. DOI: 10.3390/jcm13123596.


Current concept: personalized alignment total knee arthroplasty as a contrast to classical mechanical alignment total knee arthroplasty.

Hiranaka T Arthroplasty. 2024; 6(1):23.

PMID: 38705976 PMC: 11071279. DOI: 10.1186/s42836-024-00246-2.