» Articles » PMID: 2492185

Pneumothorax Due to Nasogastric Feeding Tubes. Report of Four Cases, Review of the Literature, and Recommendations for Prevention

Overview
Journal Arch Intern Med
Specialty General Medicine
Date 1989 Jan 1
PMID 2492185
Citations 29
Authors
Affiliations
Soon will be listed here.
Abstract

Intrapulmonary placement of small-bore nasogastric feeding tubes caused pneumothoraces in four patients. Review of the literature discloses another 106 cases of the same complication. Risk factors for intrapulmonary complications include endotracheal intubation or tracheostomy (60% of reported cases [95% confidence interval, 44% to 80%]), and altered mental status (36% of reported cases [95% confidence interval, 24% to 53%]). We propose a simple, two-step method of feeding tube insertion designed to prevent such complications in high-risk patients.

Citing Articles

A biologically transparent illumination device is more useful in children for detecting the position of the nasogastric tube in the stomach.

Satake R, Yamakawa H, Aoki N, Tanaka R, Yoshimoto S, Okunobo T Pediatr Surg Int. 2024; 40(1):275.

PMID: 39460791 DOI: 10.1007/s00383-024-05854-2.


A Case Report of an Atypical Situation Arising During Typical Ryle's Tube Removal Procedure.

Gupta P, Vyas P, Soni N Indian J Otolaryngol Head Neck Surg. 2024; 76(1):1118-1120.

PMID: 38440552 PMC: 10908736. DOI: 10.1007/s12070-023-04147-9.


An improved biologically transparent illumination system that increases the accuracy of detecting the correct position of a nasogastric tube in the stomach.

Masaki H, Hirano H, Takahashi J, Kamada T, Masaki E PLoS One. 2023; 18(12):e0295415.

PMID: 38060505 PMC: 10703337. DOI: 10.1371/journal.pone.0295415.


A safe and simple technique for nasogastric tube insertion in patients with thoracic esophageal cancer surgery.

Hirahara N, Matsubara T, Kaji S, Uchida Y, Yamamoto T, Hyakudomi R World J Surg Oncol. 2021; 19(1):317.

PMID: 34732220 PMC: 8564989. DOI: 10.1186/s12957-021-02428-7.


X-ray checks of NG tube position: a case for guided tube placement.

Taylor S, Manara A Br J Radiol. 2021; 94(1124):20210432.

PMID: 34233513 PMC: 8764929. DOI: 10.1259/bjr.20210432.