Nonlinear Calibration Model Choice Between the Four and Five-Parameter Logistic Models

Overview
Journal J Biopharm Stat
Date 2014 Jun 12
PMID 24918306
Citations 12
Authors
Affiliations
Soon will be listed here.
Abstract

Both the four-parameter logistic (4PL) and the five-parameter logistic (5PL) models are widely used in nonlinear calibration. In this paper, we study the choice between 5PL and 4PL both by the accuracy and precision of the estimated concentrations and by the power to detect an association between a binary disease outcome and the estimated concentrations. Our results show that when the true curve is symmetric around its inflection point, the efficiency loss from using 5PL is negligible under the prevalent experimental design. When the true curve is asymmetric, 4PL may sometimes offer better performance due to bias-variance trade-off. We provide a practical guideline for choosing between 5PL and 4PL and illustrate its application with a real dataset from the HIV Vaccine Trials Network laboratory.

Citing Articles

Development of a fully automated chemiluminescent immunoassay for the quantitative and qualitative detection of antibodies against African swine fever virus p72.

Wang L, Li D, Zeng D, Wang S, Wu J, Liu Y Microbiol Spectr. 2024; 12(10):e0080924.

PMID: 39145655 PMC: 11448198. DOI: 10.1128/spectrum.00809-24.


Quantitative mRNA expression measurement at home.

Pandey S, McCoy S, Stobdan T, Sahoo D Sci Rep. 2024; 14(1):1013.

PMID: 38200031 PMC: 10781964. DOI: 10.1038/s41598-023-49651-8.


A stable physisorbed layer of packed capture antibodies for high-performance sensing applications.

Sarcina L, Scandurra C, Franco C, Caputo M, Catacchio M, Bollella P J Mater Chem C Mater. 2023; 11(27):9093-9106.

PMID: 37457868 PMC: 10341389. DOI: 10.1039/d3tc01123b.


Characterising the intensity of insecticide resistance: A novel framework for analysis of intensity bioassay data.

Kont M, Lambert B, Sanou A, Williams J, Ranson H, Foster G Curr Res Parasitol Vector Borne Dis. 2023; 4:100125.

PMID: 37456558 PMC: 10338328. DOI: 10.1016/j.crpvbd.2023.100125.


Analytical Validation of a Direct Competitive ELISA for Multiple Mycotoxin Detection in Human Serum.

Garg K, Villavicencio-Aguilar F, Solano-Rivera F, Gilbert L Toxins (Basel). 2022; 14(11).

PMID: 36355977 PMC: 9694295. DOI: 10.3390/toxins14110727.


References
1.
Nottingham Q, Birch J . A semiparametric approach to analysing dose-response data. Stat Med. 2000; 19(3):389-404. DOI: 10.1002/(sici)1097-0258(20000215)19:3<389::aid-sim326>3.0.co;2-j. View

2.
Faes C, Aerts M, Geys H, Molenberghs G . Model averaging using fractional polynomials to estimate a safe level of exposure. Risk Anal. 2007; 27(1):111-23. DOI: 10.1111/j.1539-6924.2006.00863.x. View

3.
Fong Y, Wakefield J, De Rosa S, Frahm N . A robust bayesian random effects model for nonlinear calibration problems. Biometrics. 2012; 68(4):1103-12. PMC: 3897249. DOI: 10.1111/j.1541-0420.2012.01762.x. View

4.
FINNEY D . Radioligand Assay. Biometrics. 1976; 32(4):721-40. View

5.
Fong Y, Sebestyen K, Yu X, Gilbert P, Self S . nCal: an R package for non-linear calibration. Bioinformatics. 2013; 29(20):2653-4. PMC: 3789552. DOI: 10.1093/bioinformatics/btt456. View