» Articles » PMID: 24875733

Factors Influencing K-wire Migration in Tension-band Wiring of Olecranon Fractures

Overview
Date 2014 May 31
PMID 24875733
Citations 18
Authors
Affiliations
Soon will be listed here.
Abstract

Background: Tension-band wiring is a popular method of internal fixation for simple olecranon fractures. Although fracture union rates and clinical outcomes are good, up to 80% of patients require removal because of prominent/symptomatic metalwork. The current literature remains unclear as to the best orientation of the longitudinal wires to minimize hardware failure. The aim of this study was to determine the surgically modifiable factors related to spontaneous wire pullout.

Methods: A retrospective review of hospital theater records over a period of 6 years was performed to identify all olecranon tension-band wire procedures. Preoperative radiographs were used to confirm and classify the fracture. Intraoperative and postoperative radiographs were analyzed for a number of wire-associated variables: wire length within the ulna, medullary/cortical position, parallelism of wires, proximal wire prominence, wire angle relative to the ulna, distance from the articular surface, fracture gap, and subsequent pullout.

Results: A total of 182 wires were analyzed. The mean age was 52.5 years, and the mean radiographic follow-up period was 7.3 months. Intramedullary wires had a mean pullout of 5.5 mm compared with 2.4 mm for transcortical wires (P < .0001). A multiple regression model noted 7 independent variables affecting wire pullout: age, bent wires, medullary/transcortical wire positioning, proximal prominence, ulnar shaft angle, distance from the articular surface, and articular step.

Conclusion: To minimize postoperative pullout of wires, we suggest anatomic reduction and transcortical wire orientation, without bending, in the subchondral bone close to the articular surface.

Citing Articles

Fixation of Olecranon Fractures Using a Hybrid Intramedullary Screw and Tension Band Construct.

Rush K, Fisher J, Jain N, Gottlich C, Caroom C Adv Orthop. 2024; 2024:6471544.

PMID: 38845777 PMC: 11156510. DOI: 10.1155/2024/6471544.


A rare complication of tension band fixation of olecranon osteotomy: Distal migration of K-wire.

Koroglu M, Karakaplan M, Ergen E, Eren M, Alyousef A, Ozdes H Jt Dis Relat Surg. 2024; 35(2):439-442.

PMID: 38727126 PMC: 11128946. DOI: 10.52312/jdrs.2024.1662.


Locked Tension Band Wiring: A Modified Technique for Olecranon Fractures-A Multicenter Study Comparing Clinical Outcomes and Complications with Conventional Methods.

Kuwahara Y, Takegami Y, Mitsuya S, Tokutake K, Yamauchi K, Imagama S Indian J Orthop. 2023; 57(12):2024-2030.

PMID: 38009177 PMC: 10673746. DOI: 10.1007/s43465-023-01017-y.


The With Or Without Olecranon K-wire (WOW OK) Trial of tension band wire fixation versus cerclage fixation without K-wires in displaced stable olecranon fractures: study protocol for a randomized controlled trial.

Cornefjord G, Kostogiannis I, Rogmark C, Jerrhag D, Wenger D Trials. 2023; 24(1):559.

PMID: 37641082 PMC: 10464474. DOI: 10.1186/s13063-023-07566-9.


Individualized 3D-printed navigation template-assisted tension band wiring for olecranon fractures.

Xiong X, Chen Y, Zhao L, Li H, Xu M, Shuang F J Orthop Surg Res. 2023; 18(1):407.

PMID: 37271815 PMC: 10240789. DOI: 10.1186/s13018-023-03892-5.