» Articles » PMID: 24838426

Radiographic and Clinical Assessment on the Accuracy and Complications of C1 Anterior Lateral Mass and C2 Anterior Pedicle Screw Placement in the TARP-III Procedure: a Study of 106 Patients

Overview
Journal Eur Spine J
Specialty Orthopedics
Date 2014 May 20
PMID 24838426
Citations 5
Authors
Affiliations
Soon will be listed here.
Abstract

Purpose: To investigate the (1) radiographic and clinical accuracy of C1 anterior lateral mass screw (C1ALMS) and C2 anterior pedicle screw (C2APS) placement in the transoral atlantoaxial reduction plate (TARP)-III procedure, (2) screw insertion-associated clinical complications and (3) fusion status between C1 and C2.

Methods: Radiographic and clinical data were obtained from the electronic medical record system. Studies were carried out to assess the accuracy of C1ALMS and C2APS placement, the screw insertion-associated clinical complications and the fusion status between C1 and C2. Placement of the screws was assessed using the modified All India Institute of Medical Sciences outcome-based classification.

Results: Two-hundred and twelve C1ALMS and 207 C2APS in 106 patients were assessed. The ideal accurate rates were 92.0% (195) and 53.1% (110), and the acceptable accurate rates were 97.6% (207) and 87.0% (180), respectively. One patient died postoperatively due to C2 screw misplacement. There were no symptoms of neurologic and vertebral artery injuries in the rest of the patients. 102 patients (97.1%) achieved solid fusion between C1 and C2. No instrumentation failure due to delayed union or nonunion was observed.

Conclusion: C1ALMS placement in TARP-III procedures appears to be safe. The cortical breach rate of C2APS is high though clinically the neurovascular complication rate is similar to that of posterior atlantoaxial procedures. Advanced navigation strategies may help improve the accuracy of C2APS placement and decrease potential complications.

Citing Articles

Transoral Atlantoaxial Reduction Plate (TARP) Technique for the Treatment of Irreducible Atlantoaxial Dislocation (IAAD) Caused by Old Odontoid Fracture.

Zou X, Cai M, Yang H, Zhang S, Deng C, Chen J Global Spine J. 2024; :21925682241299711.

PMID: 39514298 PMC: 11559942. DOI: 10.1177/21925682241299711.


Preoperative management and postoperative complications associated with transoral decompression for the upper cervical spine.

Li W, Wang B, Feng X, Hua W, Yang C BMC Musculoskelet Disord. 2022; 23(1):128.

PMID: 35135526 PMC: 8826709. DOI: 10.1186/s12891-022-05081-7.


An Intraoperative Trajectory-Determined Strategy of Patient-Specific Drill Template for C Transoral Pedicle Insertion in Incomplete Reduction of Atlantoaxial Dislocation: An In Vitro Study.

Shan J, Zhu M, Li L, Peng P, Dai M, Lin L Orthop Surg. 2021; 13(5):1646-1653.

PMID: 34096172 PMC: 8313163. DOI: 10.1111/os.13049.


Patient-specific drill template for C2 transoral pedicle insertion in complete reduction of atlantoaxial dislocation: cadaveric efficacy and accuracy assessments.

Lin L, Zhu M, Peng P, Zhang X, Zhou X, Li J J Orthop Surg Res. 2019; 14(1):141.

PMID: 31096990 PMC: 6524296. DOI: 10.1186/s13018-019-1189-7.


Biomechanical comparison of a novel transoral atlantoaxial anchored cage with established fixation technique - a finite element analysis.

Zhang B, Liu H, Cai X, Wang Z, Xu F, Kang H BMC Musculoskelet Disord. 2015; 16:261.

PMID: 26395763 PMC: 4579577. DOI: 10.1186/s12891-015-0662-7.

References
1.
Kandziora F, Khodadadyan-Klostermann C, Schroder R, Mittlmeier T . Screw placement in transoral atlantoaxial plate systems: an anatomical study. J Neurosurg. 2001; 95(1 Suppl):80-7. DOI: 10.3171/spi.2001.95.1.0080. View

2.
Aryan H, Newman C, Nottmeier E, Acosta Jr F, Wang V, Ames C . Stabilization of the atlantoaxial complex via C-1 lateral mass and C-2 pedicle screw fixation in a multicenter clinical experience in 102 patients: modification of the Harms and Goel techniques. J Neurosurg Spine. 2008; 8(3):222-9. DOI: 10.3171/SPI/2008/8/3/222. View

3.
Kandziora F, Pflugmacher R, Ludwig K, Duda G, Mittlmeier T, Haas N . Biomechanical comparison of four anterior atlantoaxial plate systems. J Neurosurg. 2002; 96(3 Suppl):313-20. DOI: 10.3171/spi.2002.96.3.0313. View

4.
Stulik J, Vyskocil T, Sebesta P, Kryl J . Atlantoaxial fixation using the polyaxial screw-rod system. Eur Spine J. 2006; 16(4):479-84. PMC: 2229812. DOI: 10.1007/s00586-006-0241-6. View

5.
Wang C, Yan M, Zhou H, Wang S, Dang G . Open reduction of irreducible atlantoaxial dislocation by transoral anterior atlantoaxial release and posterior internal fixation. Spine (Phila Pa 1976). 2006; 31(11):E306-13. DOI: 10.1097/01.brs.0000217686.80327.e4. View