» Articles » PMID: 31096990

Patient-specific Drill Template for C2 Transoral Pedicle Insertion in Complete Reduction of Atlantoaxial Dislocation: Cadaveric Efficacy and Accuracy Assessments

Overview
Publisher Biomed Central
Specialty Orthopedics
Date 2019 May 18
PMID 31096990
Citations 3
Authors
Affiliations
Soon will be listed here.
Abstract

Background: The transoral atlantoaxial reduction plate (TARP) is an effective advance in the treatment of atlantoaxial dislocation (AAD) and can enable the performance of anterior atlantoaxial release, reduction, decompression, and internal fixation in a one-stage operation. However, accurate transoral C2 pedicle insertion (C2TOPI) remains a challenge. The aim of this study is to develop a grouped patient-specific drill template (PDT) specifically for AAD with complete reduction and, furthermore, to compare its efficacy and accuracy in facilitating C2TOPI.

Methods: After CT scanning, ten cadaveric C2 specimens were randomly assigned to two groups (the PDT and freehand group). A grouped PDT specifically for AAD with complete reduction was designed and manufactured. C2TOPI was performed using the PDT or the fluoroscopy-guided freehand technique. Postoperative CT scans were subsequently performed to analyze the deviations at the centroid of the cross section at the midpoint of the pedicle. Screw position grades were also assessed in both groups.

Results: Compared to the freehand group, the PDT group had a significantly shorter surgery time (p < 0.001). Significant differences between the two groups were observed in the absolute value of the deviations at the centroid of the pedicle on either the axial or sagittal planes (p < 0.05). No significant difference was found in the screw positions between the two groups (p > 0.05); however, two unacceptable breaches (20%) occurred in the freehand group.

Conclusion: A specifically designed PDT could provide an accurate and easy-to-apply method for C2TOPI in AAD with complete reduction.

Citing Articles

The clinical validity of atlantoaxial joint inclination angle and reduction index for atlantoaxial dislocation.

Qu Y, Du Y, Zhao Y, Li J, Luo H, Zhou J Front Surg. 2023; 9:1028721.

PMID: 36684329 PMC: 9852502. DOI: 10.3389/fsurg.2022.1028721.


An Intraoperative Trajectory-Determined Strategy of Patient-Specific Drill Template for C Transoral Pedicle Insertion in Incomplete Reduction of Atlantoaxial Dislocation: An In Vitro Study.

Shan J, Zhu M, Li L, Peng P, Dai M, Lin L Orthop Surg. 2021; 13(5):1646-1653.

PMID: 34096172 PMC: 8313163. DOI: 10.1111/os.13049.


Spiral CT measurement for atlantoaxial pedicle screw trajectory and its clinical application.

Xu G, Wang D, Chen J, Hong Q, Zhuang H Am J Transl Res. 2021; 13(4):2555-2562.

PMID: 34017414 PMC: 8129255.

References
1.
Xu R, Kang A, Ebraheim N, Yeasting R . Anatomic relation between the cervical pedicle and the adjacent neural structures. Spine (Phila Pa 1976). 1999; 24(5):451-4. DOI: 10.1097/00007632-199903010-00008. View

2.
Rampersaud Y, Foley K, Shen A, Williams S, Solomito M . Radiation exposure to the spine surgeon during fluoroscopically assisted pedicle screw insertion. Spine (Phila Pa 1976). 2000; 25(20):2637-45. DOI: 10.1097/00007632-200010150-00016. View

3.
Berry E, Cuppone M, Porada S, Millner P, Rao A, Chiverton N . Personalised image-based templates for intra-operative guidance. Proc Inst Mech Eng H. 2005; 219(2):111-8. DOI: 10.1243/095441105X9273. View

4.
Ondra S, Marzouk S, Ganju A, Morrison T, Koski T . Safety and efficacy of C2 pedicle screws placed with anatomic and lateral C-arm guidance. Spine (Phila Pa 1976). 2006; 31(9):E263-7. DOI: 10.1097/01.brs.0000214882.34674.be. View

5.
Liu G, Buchowski J, Shen H, Yeom J, Riew K . The feasibility of microscope-assisted "free-hand" C1 lateral mass screw insertion without fluoroscopy. Spine (Phila Pa 1976). 2008; 33(9):1042-9. DOI: 10.1097/BRS.0b013e31816d72b5. View