Image Reconstruction in K-space from MR Data Encoded with Ambiguous Gradient Fields

Overview
Journal Magn Reson Med
Publisher Wiley
Specialty Radiology
Date 2014 Apr 30
PMID 24777559
Citations 4
Authors
Affiliations
Soon will be listed here.
Abstract

Purpose: In this work, the limits of image reconstruction in k-space are explored when non-bijective gradient fields are used for spatial encoding.

Theory: The image space analogy between parallel imaging and imaging with non-bijective encoding fields is partially broken in k-space. As a consequence, it is hypothesized and proven that ambiguities can only be resolved partially in k-space, and not completely as is the case in image space.

Methods: Image-space and k-space based reconstruction algorithms for multi-channel radiofrequency data acquisitions are programmed and tested using numerical simulations as well as in vivo measurement data.

Results: The hypothesis is verified based on an analysis of reconstructed images. It is found that non-bijective gradient fields have the effect that densely sampled autocalibration data, used for k-space reconstruction, provide less information than a separate scan of the receiver coil sensitivity maps, used for image space reconstruction. Consequently, in k-space only the undersampling artifact can be unfolded, whereas in image space, it is also possible to resolve aliasing that is caused by the non-bijectivity of the gradient fields.

Conclusion: For standard imaging, reconstruction in image space and in k-space is nearly equivalent, whereas there is a fundamental difference with practical consequences for the selection of image reconstruction algorithms when non-bijective encoding fields are involved.

Citing Articles

Switching Circuit Optimization for Matrix Gradient Coils.

Kroboth S, Layton K, Jia F, Littin S, Yu H, Hennig J Tomography. 2019; 5(2):248-259.

PMID: 31245546 PMC: 6588200. DOI: 10.18383/j.tom.2018.00056.


Clinical Potential of a New Approach to MRI Acceleration.

Dispenza N, Littin S, Zaitsev M, Constable R, Galiana G Sci Rep. 2019; 9(1):1912.

PMID: 30760731 PMC: 6374397. DOI: 10.1038/s41598-018-36802-5.


Fast rotary nonlinear spatial acquisition (FRONSAC) imaging.

Wang H, Tam L, Constable R, Galiana G Magn Reson Med. 2015; 75(3):1154-65.

PMID: 25950279 PMC: 4637004. DOI: 10.1002/mrm.25703.


Image reconstruction in k-space from MR data encoded with ambiguous gradient fields.

Schultz G, Gallichan D, Weber H, Witschey W, Honal M, Hennig J Magn Reson Med. 2014; 73(2):857-64.

PMID: 24777559 PMC: 4617561. DOI: 10.1002/mrm.25152.

References
1.
Griswold M, Jakob P, Heidemann R, Nittka M, Jellus V, Wang J . Generalized autocalibrating partially parallel acquisitions (GRAPPA). Magn Reson Med. 2002; 47(6):1202-10. DOI: 10.1002/mrm.10171. View

2.
Parot V, Sing-Long C, Lizama C, Tejos C, Uribe S, Irarrazaval P . Application of the fractional Fourier transform to image reconstruction in MRI. Magn Reson Med. 2011; 68(1):17-29. DOI: 10.1002/mrm.23190. View

3.
Blaimer M, Breuer F, Seiberlich N, Mueller M, Heidemann R, Jellus V . Accelerated volumetric MRI with a SENSE/GRAPPA combination. J Magn Reson Imaging. 2006; 24(2):444-50. DOI: 10.1002/jmri.20632. View

4.
Pruessmann K, Weiger M, Scheidegger M, Boesiger P . SENSE: sensitivity encoding for fast MRI. Magn Reson Med. 1999; 42(5):952-62. View

5.
Gallichan D, Cocosco C, Dewdney A, Schultz G, Welz A, Hennig J . Simultaneously driven linear and nonlinear spatial encoding fields in MRI. Magn Reson Med. 2011; 65(3):702-14. DOI: 10.1002/mrm.22672. View