Establishment of a Swine Model for Validation of Perfusion Measurement by Dynamic Contrast-enhanced Magnetic Resonance Imaging
Overview
Biotechnology
General Medicine
Authors
Affiliations
The aim of the study was to develop a suitable animal model for validating dynamic contrast-enhanced magnetic resonance imaging perfusion measurements. A total of 8 pigs were investigated by DCE-MRI. Perfusion was determined on the hind leg musculature. An ultrasound flow probe placed around the femoral artery provided flow measurements independent of MRI and served as the standard of reference. Images were acquired on a 1.5 T MRI scanner using a 3D T1-weighted gradient-echo sequence. An arterial catheter for local injection was implanted in the femoral artery. Continuous injection of adenosine for vasodilation resulted in steady blood flow levels up to four times the baseline level. In this way, three different stable perfusion levels were induced and measured. A central venous catheter was used for injection of two different types of contrast media. A low-molecular weight contrast medium and a blood pool contrast medium were used. A total of 6 perfusion measurements were performed with a time interval of about 20-25 min without significant differences in the arterial input functions. In conclusion the accuracy of DCE-MRI-based perfusion measurement can be validated by comparison of the integrated perfusion signal of the hind leg musculature with the blood flow values measured with the ultrasound flow probe around the femoral artery.
A soft thermal sensor for the continuous assessment of flow in vascular access.
Deng Y, Arafa H, Yang T, Albadawi H, Fowl R, Zhang Z Nat Commun. 2025; 16(1):38.
PMID: 39746935 PMC: 11696732. DOI: 10.1038/s41467-024-54942-3.
A novel methodology for mapping interstitial fluid dynamics in murine brain tumors using DCE-MRI.
Carman-Esparza C, Kingsmore K, Vaccari A, Davis S, Cunningham J, Wang M Methods. 2024; 231:78-93.
PMID: 39284430 PMC: 11851864. DOI: 10.1016/j.ymeth.2024.09.008.
Hindel S Bull Math Biol. 2024; 86(3):26.
PMID: 38300429 DOI: 10.1007/s11538-023-01255-z.
Haemodynamics Imaging of Swine Segmental Kidney Artery Using Duplex Doppler Technique.
Aleksiewicz R, Lutnicki K, Bojarski M, Al-Mutari I, Bochenska A J Vet Res. 2019; 63(2):259-265.
PMID: 31276066 PMC: 6598193. DOI: 10.2478/jvetres-2019-0036.
Eickel K, Andrew Porter D, Sohner A, Maass M, Ludemann L, Gunther M PLoS One. 2018; 13(8):e0202673.
PMID: 30153275 PMC: 6112664. DOI: 10.1371/journal.pone.0202673.