Absolute Myocardial Perfusion in Canines Measured by Using Dual-bolus First-pass MR Imaging

Overview
Journal Radiology
Specialty Radiology
Date 2004 Jul 31
PMID 15284436
Citations 114
Authors
Affiliations
Soon will be listed here.
Abstract

Purpose: To compare fluorescent microsphere measurements of myocardial blood flow (MBF) with qualitative, semiquantitative, and fully quantitative measurements of first-pass perfusion at magnetic resonance (MR) imaging.

Materials And Methods: Coronary artery occlusion or intracoronary adenosine infusion was successfully performed in 16 beagles; both procedures were performed simultaneously in one animal. MBF was assessed at microsphere analysis. First-pass myocardial perfusion MR imaging was performed during a dual-bolus administration of gadopentetate dimeglumine (0.0025 mmol/kg followed by 0.10 mmol/kg). The absolute myocardial perfusion at MR imaging was calculated by using Fermi function deconvolution methods. Qualitative, semiquantitative, and absolute myocardial perfusion MR imaging measurements were compared with microsphere MBF measurements by using paired t tests, linear correlation, and Bland-Altman analysis.

Results: Fully quantitative (ie, absolute) analysis of MBF at MR imaging correlated with microsphere MBF measurement (r = 0.95, P <.001) across the full range of blood flow rates encountered (from 0 to >5.0 mL/min/g). Similar close correlations were observed in endocardial and epicardial segments (representing approximately 0.85 g of the myocardium). With modest increases in MBF, qualitative measurements plateaued in the hyperemic zones. Semiquantitative measurements did not correlate with MBF as well (r = 0.69-0.89); they plateaued around 3.0 mL/min/g.

Conclusion: Dual-bolus MR imaging enabled accurate measurement of absolute epicardial and endocardial perfusion across a wide range of blood flow rates (0 to >5.0 mL/min/g). Use of qualitative MR imaging measures such as the contrast enhancement ratio led to substantially underestimated hyperemic blood flow measurements.

Citing Articles

Multimodality Imaging in the Diagnosis of Coronary Microvascular Disease: An Update.

Martins A, Nobre Menezes M, Alves da Silva P, Almeida A J Pers Med. 2025; 15(2).

PMID: 39997350 PMC: 11856700. DOI: 10.3390/jpm15020075.


State-of-the-Art of Myocardial Perfusion by CMR: A Practical View.

Pons-Llado G, Kellman P Rev Cardiovasc Med. 2024; 23(10):325.

PMID: 39077124 PMC: 11267340. DOI: 10.31083/j.rcm2310325.


Clinical implementation of a fully automated quantitative perfusion cardiovascular magnetic resonance imaging workflow with a simplified dual-bolus contrast administration scheme.

Borodzicz-Jazdzyk S, Vink C, Demirkiran A, Hoek R, de Mooij G, Hofman M Sci Rep. 2024; 14(1):9665.

PMID: 38671061 PMC: 11053149. DOI: 10.1038/s41598-024-60503-x.


Diagnostic confidence with quantitative cardiovascular magnetic resonance perfusion mapping increases with increased coverage of the left ventricle.

Engblom H, Ostenfeld E, Carlsson M, Akesson J, Aletras A, Xue H J Cardiovasc Magn Reson. 2024; 26(1):101007.

PMID: 38316344 PMC: 11211224. DOI: 10.1016/j.jocmr.2024.101007.


Letter to the Editor: "Fully automated pixel-wise quantitative CMR-myocardial perfusion with CMR-coronary angiography to detect hemodynamically significant coronary artery disease".

Borodzicz-Jazdzyk S, Gotte M Eur Radiol. 2023; 34(4):2711-2713.

PMID: 37831141 DOI: 10.1007/s00330-023-10293-z.