» Articles » PMID: 24627731

Mid Term Results of Distal Femoral Fractures Treated with a Polyaxial Locking Plate: a Multi-center Study

Overview
Journal Open Orthop J
Publisher Bentham Open
Specialty Orthopedics
Date 2014 Mar 15
PMID 24627731
Citations 7
Authors
Affiliations
Soon will be listed here.
Abstract

Objective: Locking plates have become a standard implant in the treatment of distal femoral fractures. Newer designs allow polyaxial screw placement as well as the ability to lock the lag screws.

Methods: The consecutive multi-centre study cohort consists of all distal femoral fractures treated with the NCB® Distal Femur plate (Zimmer, Warsaw, USA) and a minimum follow-up of twelve months. Fracture classification according the AO/ OTA system and the trauma mechanism radiological evaluation and complications were documented. Clinical evaluation consisted of the Short Form SF12 questionnaire (SF12), the Hospital for Special Surgery Score (HSS) and clinical assessment of range of motion.

Results: Twenty-five patients with twenty-six fractures were available for follow-up with a minimum required follow-up of twelve months. 81% of the fractures were intra-articular. 48% of the patients were multi-traumatised, 38% having open fractures. All except two went to union (92%) with the primary procedure. The HSS Score was 79 (32-99) and the SF 12 (physical and mental) 40 (19-57) and 54 (21-66) at follow-up. There were five patients requiring surgical revision (19%).

Conclusion: These fractures are often combined with concomitant injuries. Using modern locked implants high union rates can be achieved with a good function and patient satisfaction when respecting biologic and biomechanical principles.

Citing Articles

Total femur fixation using the "nail-plate docking technique" for ipsilateral femur shaft fracture.

Takai H, Nonoue Y, Kitajima M, Hama S, Takahashi T Trauma Case Rep. 2022; 42:100722.

PMID: 36281428 PMC: 9587334. DOI: 10.1016/j.tcr.2022.100722.


Patient experience from a doctor's perspective: A case report concerning treatment, fracture healing and rehabilitation of multiple complex injuries due to a high energy motor vehicle collision.

de Ruijter M, Lucke J, Yuan J, Derksen R Trauma Case Rep. 2022; 42:100699.

PMID: 36210916 PMC: 9535306. DOI: 10.1016/j.tcr.2022.100699.


Comparing Intramedullary Nailing Versus Locked Plating in the Treatment of Native Distal Femur Fractures: .

Jankowski J, Szukics P, Shah J, Keller D, Pires R, Liporace F Indian J Orthop. 2021; 55(3):646-654.

PMID: 33995868 PMC: 8081772. DOI: 10.1007/s43465-020-00331-z.


Incidence of nonunion after surgery of distal femoral fractures using contemporary fixation device: a meta-analysis.

Yoon B, Park I, Kim Y, Oh H, Choo S, Sung Y Arch Orthop Trauma Surg. 2020; 141(2):225-233.

PMID: 32388648 DOI: 10.1007/s00402-020-03463-x.


Outcomes of distal femur fractures treated with the Synthes 4.5 mm VA-LCP Curved Condylar Plate.

Dang K, Armstrong C, Karia R, Zelle B Int Orthop. 2018; 43(7):1709-1714.

PMID: 30267242 DOI: 10.1007/s00264-018-4177-3.


References
1.
Kregor P, Stannard J, Zlowodzki M, Cole P . Treatment of distal femur fractures using the less invasive stabilization system: surgical experience and early clinical results in 103 fractures. J Orthop Trauma. 2004; 18(8):509-20. DOI: 10.1097/00005131-200409000-00006. View

2.
Henderson C, Lujan T, Kuhl L, Bottlang M, Fitzpatrick D, Marsh J . 2010 mid-America Orthopaedic Association Physician in Training Award: healing complications are common after locked plating for distal femur fractures. Clin Orthop Relat Res. 2011; 469(6):1757-65. PMC: 3094618. DOI: 10.1007/s11999-011-1870-6. View

3.
Greiwe R, Archdeacon M . Locking plate technology: current concepts. J Knee Surg. 2007; 20(1):50-5. DOI: 10.1055/s-0030-1248022. View

4.
Erhardt J, Grob K, Roderer G, Hoffmann A, Forster T, Kuster M . Treatment of periprosthetic femur fractures with the non-contact bridging plate: a new angular stable implant. Arch Orthop Trauma Surg. 2007; 128(4):409-16. DOI: 10.1007/s00402-007-0396-6. View

5.
Frigg R . Locking Compression Plate (LCP). An osteosynthesis plate based on the Dynamic Compression Plate and the Point Contact Fixator (PC-Fix). Injury. 2001; 32 Suppl 2:63-6. DOI: 10.1016/s0020-1383(01)00127-9. View