» Articles » PMID: 24558593

Reproducibility of Retinal Nerve Fiber Layer Measurements with Manual and Automated Centration in Healthy Subjects Using Spectralis Spectral-domain Optical Coherence Tomography

Overview
Journal ISRN Ophthalmol
Specialty Ophthalmology
Date 2014 Feb 22
PMID 24558593
Citations 3
Authors
Affiliations
Soon will be listed here.
Abstract

Objective. The aim of this study was to test the reproducibility of the Heidelberg Spectralis SD-OCT and to determine if provided software retest function for follow-up exam is superior to manual centration. Design. Prospective, cross-sectional study. Participants. 20 healthy subjects. Methods. All subjects underwent SD-OCT testing to determine retinal nerve fiber layer (RNFL) measurements sequentially on two different days and with two different centration techniques. Within-subject standard deviation, coefficient of variation, and intraclass correlation coefficient were used to assess reproducibility. Results. RNFL measurements showed high reproducibility, low within-subject standard deviation (1.3), low coefficient of variation (0.63%), and low intra-class correlation coefficient (0.98 (95% CI 0.97-0.99)) in the automated centration and manual centration groups for average RNFL Thickness. Quadrants showed slightly higher variability in the manual group compared to the automated group (within-subject standard deviation 2.5-5.3 versus 1.1-2.4, resp.). Conclusions. SD-OCT provides high-resolution RNFL measurements with high reproducibility and low variability. The re-test function allows for easier recentration for longitudinal examinations with similar results in average RNFL, but less variability in quadrant RNFL. SD-OCT high reproducibility and low variability is a promising fact and should be further evaluated in longitudinal studies of RNFL.

Citing Articles

Optical coherence tomography in multiple sclerosis: A 3-year prospective multicenter study.

Paul F, Calabresi P, Barkhof F, Green A, Kardon R, Sastre-Garriga J Ann Clin Transl Neurol. 2021; 8(12):2235-2251.

PMID: 34792863 PMC: 8670323. DOI: 10.1002/acn3.51473.


Diagnostic Capability of Peripapillary Three-dimensional Retinal Nerve Fiber Layer Volume for Glaucoma Using Optical Coherence Tomography Volume Scans.

Khoueir Z, Jassim F, Poon L, Tsikata E, Ben-David G, Liu Y Am J Ophthalmol. 2017; 182:180-193.

PMID: 28807732 PMC: 5610646. DOI: 10.1016/j.ajo.2017.08.001.


Comparison of Optical Coherence Tomography Measurement Reproducibility between Children and Adults.

Chung H, Han Y, Oh S, Kim S PLoS One. 2016; 11(1):e0147448.

PMID: 26808961 PMC: 4726508. DOI: 10.1371/journal.pone.0147448.

References
1.
Sakamoto A, Hangai M, Yoshimura N . Spectral-domain optical coherence tomography with multiple B-scan averaging for enhanced imaging of retinal diseases. Ophthalmology. 2007; 115(6):1071-1078.e7. DOI: 10.1016/j.ophtha.2007.09.001. View

2.
Gonzalez-Garcia A, Vizzeri G, Bowd C, Medeiros F, Zangwill L, Weinreb R . Reproducibility of RTVue retinal nerve fiber layer thickness and optic disc measurements and agreement with Stratus optical coherence tomography measurements. Am J Ophthalmol. 2009; 147(6):1067-74, 1074.e1. PMC: 3465966. DOI: 10.1016/j.ajo.2008.12.032. View

3.
Savini G, Barboni P, Carbonelli M, Zanini M . The effect of scan diameter on retinal nerve fiber layer thickness measurement using stratus optic coherence tomography. Arch Ophthalmol. 2007; 125(7):901-5. DOI: 10.1001/archopht.125.7.901. View

4.
Serbecic N, Beutelspacher S, Aboul-Enein F, Kircher K, Reitner A, Schmidt-Erfurth U . Reproducibility of high-resolution optical coherence tomography measurements of the nerve fibre layer with the new Heidelberg Spectralis optical coherence tomography. Br J Ophthalmol. 2010; 95(6):804-10. DOI: 10.1136/bjo.2010.186221. View

5.
Talman L, Bisker E, Sackel D, Long Jr D, Galetta K, Ratchford J . Longitudinal study of vision and retinal nerve fiber layer thickness in multiple sclerosis. Ann Neurol. 2010; 67(6):749-60. PMC: 2901775. DOI: 10.1002/ana.22005. View