» Articles » PMID: 24505739

Self-gated Radial MRI for Respiratory Motion Compensation on Hybrid PET/MR Systems

Overview
Publisher Springer
Date 2014 Feb 8
PMID 24505739
Citations 21
Authors
Affiliations
Soon will be listed here.
Abstract

Accurate localization and uptake quantification of lesions in the chest and abdomen using PET imaging is challenging due to the respiratory motion during the exam. The advent of hybrid PET/MR systems offers new ways to compensate for respiratory motion without exposing the patient to additional radiation. The use of self-gated reconstructions of a 3D radial stack-of-stars GRE acquisition is proposed to derive a high-resolution MRI motion model. The self-gating signal is used to perform respiratory binning of the simultaneously acquired PET raw data. Matching mu-maps are generated for every bin, and post-reconstruction registration is performed in order to obtain a motion-compensated PET volume from the individual gates. The proposed method is demonstrated in-vivo for three clinical patients. Motion-corrected reconstructions are compared against ungated and gated PET reconstructions. In all cases, motion-induced blurring of lesions in the liver and lung was substantially reduced, without compromising SNR as it is the case for gated reconstructions.

Citing Articles

Free-Breathing High-Resolution, Swap-Free, and Motion-Corrected Water/Fat Separation in Pediatric Abdominal MRI.

Nosrati R, Calakli F, Afacan O, Pelkola K, Nichols R, Connaughton P Invest Radiol. 2024; 59(12):805-812.

PMID: 38857418 PMC: 11560742. DOI: 10.1097/RLI.0000000000001092.


Comparison of weighting algorithms to mitigate respiratory motion in free-breathing neonatal pulmonary radial UTE-MRI.

Gandhi D, Higano N, Hahn A, Gunatilaka C, Torres L, Fain S Biomed Phys Eng Express. 2024; 10(3.

PMID: 38599190 PMC: 11182662. DOI: 10.1088/2057-1976/ad3cdd.


On the correction of respiratory motion-induced image reconstruction errors in positron-emission tomography-guided radiation therapy.

Zhong H, Ren L, Lu Y, Liu Y Phys Imaging Radiat Oncol. 2023; 26:100430.

PMID: 36970447 PMC: 10036920. DOI: 10.1016/j.phro.2023.100430.


Free-Breathing Phase-Resolved Oxygen-Enhanced Pulmonary MRI Based on 3D Stack-of-Stars UTE Sequence.

Xu P, Zhang J, Nan Z, Meersmann T, Wang C Sensors (Basel). 2022; 22(9).

PMID: 35590959 PMC: 9105788. DOI: 10.3390/s22093270.


Golden-Angle Radial MRI: Basics, Advances, and Applications.

Feng L J Magn Reson Imaging. 2022; 56(1):45-62.