» Articles » PMID: 24458746

The Classical Starling Resistor Model Often Does Not Predict Inspiratory Airflow Patterns in the Human Upper Airway

Overview
Date 2014 Jan 25
PMID 24458746
Citations 14
Authors
Affiliations
Soon will be listed here.
Abstract

The upper airway is often modeled as a classical Starling resistor, featuring a constant inspiratory airflow, or plateau, over a range of downstream pressures. However, airflow tracings from clinical sleep studies often show an initial peak before the plateau. To conform to the Starling model, the initial peak must be of small magnitude or dismissed as a transient. We developed a method to simulate fast or slow inspirations through the human upper airway, to test the hypothesis that this initial peak is a transient. Eight subjects [4 obstructive sleep apnea (OSA), 4 controls] slept in an "iron lung" and wore a nasal mask connected to a continuous/bilevel positive airway pressure machine. Downstream pressure was measured using an epiglottic catheter. During non-rapid eye movement (NREM) sleep, subjects were hyperventilated to produce a central apnea, then extrathoracic pressure was decreased slowly (∼2-4 s) or abruptly (<0.5 s) to lower downstream pressure and create inspiratory airflow. Pressure-flow curves were constructed for flow-limited breaths, and slow vs. fast reductions in downstream pressure were compared. All subjects exhibited an initial peak and then a decrease in flow with more negative pressures, demonstrating negative effort dependence (NED). The rate of change in downstream pressure did not affect the peak to plateau airflow ratio: %NED 22 ± 13% (slow) vs. 20 ± 5% (fast), P = not significant. We conclude that the initial peak in inspiratory airflow is not a transient but rather a distinct mechanical property of the upper airway. In contrast to the classical Starling resistor model, the upper airway exhibits marked NED in some subjects.

Citing Articles

Comparison of Four Mechanical Insufflation-Exsufflation Devices: Effect of Simulated Airway Collapse on Cough Peak Flow.

Terzi N, Vaugier I, Guerin C, Prigent H, Boussaid G, Leroux K Respir Care. 2023; 68(4):462-469.

PMID: 36963968 PMC: 10173116. DOI: 10.4187/respcare.10086.


The impact of daytime transoral neuromuscular stimulation on upper airway physiology - A mechanistic clinical investigation.

Nokes B, Schmickl C, Brena R, Bosompra N, Gilbertson D, Sands S Physiol Rep. 2022; 10(12):e15360.

PMID: 35748091 PMC: 9226850. DOI: 10.14814/phy2.15360.


Critical to Know Pcrit: A Review on Pharyngeal Critical Closing Pressure in Obstructive Sleep Apnea.

Kazemeini E, Van de Perck E, Dieltjens M, Willemen M, Verbraecken J, Op de Beeck S Front Neurol. 2022; 13:775709.

PMID: 35273554 PMC: 8901991. DOI: 10.3389/fneur.2022.775709.


Pathogenesis of obstructive sleep apnea in individuals with the COPD + OSA Overlap syndrome versus OSA alone.

Orr J, Schmickl C, Edwards B, DeYoung P, Brena R, Sun X Physiol Rep. 2020; 8(3):e14371.

PMID: 32061194 PMC: 7023887. DOI: 10.14814/phy2.14371.


Precision Medicine for Obstructive Sleep Apnea.

Light M, Owens R, Schmickl C, Malhotra A Sleep Med Clin. 2019; 14(3):391-398.

PMID: 31375207 PMC: 8931687. DOI: 10.1016/j.jsmc.2019.05.005.


References
1.
Kairaitis K, Byth K, Parikh R, Stavrinou R, Wheatley J, Amis T . Tracheal traction effects on upper airway patency in rabbits: the role of tissue pressure. Sleep. 2007; 30(2):179-86. DOI: 10.1093/sleep/30.2.179. View

2.
Schwartz A, Gold A, Schubert N, Stryzak A, Wise R, PERMUTT S . Effect of weight loss on upper airway collapsibility in obstructive sleep apnea. Am Rev Respir Dis. 1991; 144(3 Pt 1):494-8. DOI: 10.1164/ajrccm/144.3_Pt_1.494. View

3.
Saboisky J, Butler J, Fogel R, Taylor J, Trinder J, White D . Tonic and phasic respiratory drives to human genioglossus motoneurons during breathing. J Neurophysiol. 2005; 95(4):2213-21. DOI: 10.1152/jn.00940.2005. View

4.
Kairaitis K, Verma M, Amatoury J, Wheatley J, White D, Amis T . A threshold lung volume for optimal mechanical effects on upper airway airflow dynamics: studies in an anesthetized rabbit model. J Appl Physiol (1985). 2012; 112(7):1197-205. DOI: 10.1152/japplphysiol.01286.2011. View

5.
Owens R, Malhotra A, Eckert D, White D, Jordan A . The influence of end-expiratory lung volume on measurements of pharyngeal collapsibility. J Appl Physiol (1985). 2009; 108(2):445-51. PMC: 3774250. DOI: 10.1152/japplphysiol.00755.2009. View