» Articles » PMID: 24453452

Treatment of Mandibular Angle Fracture with a 2mm, 3 Dimensional Rectangular Grid Compression Miniplates: A Prospective Clinical Study

Overview
Date 2014 Jan 24
PMID 24453452
Citations 1
Authors
Affiliations
Soon will be listed here.
Abstract

Background: Surgical treatment of fracture mandible using an internal fixation has changed in the last decades to achieve the required rigidity, stability and immediate restoration of function. The aim of the study was to do a Prospective study of 10 patients to determine the efficacy of rectangular grid compression miniplates in mandibular fractures.

Materials & Methods: This study was carried out using 2.0 rectangular grid compression miniplates and 8 mm multidirectional screws as a rigid internal fixation in 10 patients without post operative intermaxillary fixation (IMF). Follow up was done for period of 6 months.

Results: All fractures were healed with an absolute stability in post operative period. None of the patient complained of post operative difficulty in occlusion.

Conclusion: Within the limits of this study, it can be concluded that rectangular grid compression miniplates was rigid, reliable and thus can be recommended for the treatment of mandibular angle fractures. How to cite this article: Mansuri S, Abdulkhayum AM, Gazal G, Hussain MA. Treatment of mandibular angle fracture with a 2mm, 3 dimensional rectangular grid compression miniplates: A prospective clinical study. J Int Oral Health 2013;5(6):93-100 .

Citing Articles

A Comparative Randomized Prospective Clinical Study on Modified Erich Arch Bar with Conventional Erich Arch Bar for Maxillomandibular Fixation.

Venugopalan V, Satheesh G, Balatandayoudham A, Duraimurugan S, Balaji T Ann Maxillofac Surg. 2021; 10(2):287-291.

PMID: 33708569 PMC: 7943981. DOI: 10.4103/ams.ams_20_20.

References
1.
Bui P, Demian N, Beetar P . Infection rate in mandibular angle fractures treated with a 2.0-mm 8-hole curved strut plate. J Oral Maxillofac Surg. 2009; 67(4):804-8. DOI: 10.1016/j.joms.2008.08.034. View

2.
Farmand M . [Experiences with the 3-D miniplate osteosynthesis in mandibular fractures]. Fortschr Kiefer Gesichtschir. 1996; 41:85-7. View

3.
Zix J, Lieger O, Iizuka T . Use of straight and curved 3-dimensional titanium miniplates for fracture fixation at the mandibular angle. J Oral Maxillofac Surg. 2007; 65(9):1758-63. DOI: 10.1016/j.joms.2007.03.013. View

4.
Allan B, Daly C . Fractures of the mandible. A 35-year retrospective study. Int J Oral Maxillofac Surg. 1990; 19(5):268-71. DOI: 10.1016/s0901-5027(05)80417-5. View

5.
Champy M, Lodde J . [Mandibular synthesis. Placement of the synthesis as a function of mandibular stress]. Rev Stomatol Chir Maxillofac. 1976; 77(8):971-6. View