» Articles » PMID: 8089787

Treatment of Mandibular Angle Fractures Using Two Noncompression Miniplates

Overview
Date 1994 Oct 1
PMID 8089787
Citations 35
Authors
Affiliations
Soon will be listed here.
Abstract

Purpose: To evaluate treatment with two 2.0-mm noncompression miniplates for patients with angle fractures.

Patients And Methods: Sixty-seven consecutive patients with 69 fractures of the mandibular angle were treated by open reduction and internal fixation using two noncompression miniplates and 2.0-mm self-threading screws placed through a transoral incision with transbuccal trochar instrumentation. No patient was placed into postsurgical maxillomandibular fixation or elastics.

Results: Overall, 19 fractures (28%) experienced complications requiring secondary surgical intervention. Most of the complications were postoperative infections requiring surgical drainage (n = 17) and subsequent hardware removal (n = 16). Of the 17 infected fractures, 11 were healed at the time of hardware removal and required no further treatment. Five were still mobile and required a period of maxillomandibular fixation for healing. One of the fractures did not heal and required bone grafting.

Conclusion: The use of two noncompression miniplates was found to be relatively easy, but resulted in an unacceptable rate of infection in our patient population when used for treatment of fractures of the mandibular angle.

Citing Articles

Comparative Evaluation of Clinical Outcome Including Neurosensory Deficit and Pain Score Variables Using Rigid Internal Fixation with Three-Dimensional Miniplate Internal Fixation in Simultaneous Angle and Contralateral Body/Parasymphysis Fractures....

Kumar S, Chandran A, Hassan S, Rocchetta D, Alshammari A, Almutairi F Asian J Neurosurg. 2024; 19(3):501-512.

PMID: 39205888 PMC: 11349404. DOI: 10.1055/s-0044-1787864.


New design titanium miniplate versus conventional miniplate in treatment of mandibular angle fractures: A comparative study.

Vishnani R, Pattanshetti C, Gilani R, Sankeshwari B Natl J Maxillofac Surg. 2024; 14(3):420-425.

PMID: 38273910 PMC: 10806310. DOI: 10.4103/njms.njms_451_21.


Comparison of Single Versus Two Non-Compression Miniplates in the Management of Unfavourable Angle Fracture of the Mandible Orginal Research.

Chatterjee A, Gunashekhar S, Karthic R, Karthika S, Edsor E, Nair R J Pharm Bioallied Sci. 2023; 15(Suppl 1):S486-S489.

PMID: 37654259 PMC: 10466539. DOI: 10.4103/jpbs.jpbs_555_22.


A randomized controlled trial to compare functional, combined rigid and functional and rigid fixation in double mandibular fractures.

Pandey S, Yadav P, Roychoudhury A, Bhutia O, Goswami D J Oral Biol Craniofac Res. 2022; 12(2):233-237.

PMID: 35284226 PMC: 8913347. DOI: 10.1016/j.jobcr.2022.02.003.


Fracture Fixation Technique and Chewing Side Impact Jaw Mechanics in Mandible Fracture Repair.

Abraha H, Iriarte-Diaz J, Reid R, Ross C, Panagiotopoulou O JBMR Plus. 2022; 6(1):e10559.

PMID: 35079674 PMC: 8770999. DOI: 10.1002/jbm4.10559.